Sanyo PLC-ZM5000L RS232C Expand - Page 24

PC Adjust Control Command, 5.1 CF_FSYNC Command, 5.2 CF_TDOTS Command, 5.3 CF_CLPPHASE Command

Page 24 highlights

PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command "CF_FSYNC_%1" [CR] "0000-0031 Directly specify setting value of Fine Sync %1 "UP Increment setting value of Fine Sync by 1 "DN Decrement setting value of Fine Sync by 1 Details Set value of Fine Sync in PC signal (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. Response Acceptable Unacceptable "000" [CR] "101" [CR] --- When input is Video signal --- When input is no signal 8.5.2 CF_TDOTS Command Command "CF_TDOTS_%1" [CR] %1 Details Response "mmmm - nnnn Directly specify setting value of Total Dots "mmmm" indicates minimum value, which is current (Display area H + Position H) value "nnnn" indicates maximum value, which is less than 140 MHz in Dot Clocks "UP Increment setting value of Total Dots by 1 "DN Decrement setting value of Total Dots by 1 Set value of Total Dots in PC signal (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. Acceptable "000" [CR] Unacceptable "101" [CR] --- When input is Video signal --- When input is no signal 8.5.3 CF_CLPPHASE Command Command "CF_CLPPHASE_%1" [CR] %1 Details Response "0000-0255 Directly specify setting value of Clamp Phase "UP Increment setting value of Clamp Phase by 1 "DN Decrement setting value of Clamp Phase by 1 Set value of Clamp Phase (Available only in the normal Power ON status) The value set by this command will not be stored in the projector. Therefore, when the power is turned to ALL OFF, the value returns to the original setting. Acceptable "000" [CR] Unacceptable "101" [CR] --- When input is Video signal --- When input is no signal 24/89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
24/89
8.5
PC Adjust Control Command
8.5.1 CF_FSYNC Command
Command
“CF_FSYNC_%1” [CR]
%1
“0000-0031” ----------------- Directly specify setting value of Fine Sync
“UP” --------------------------- Increment setting value of Fine Sync by 1
“DN” --------------------------- Decrement setting value of Fine Sync by 1
Details
Set value of Fine Sync in PC signal (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting.
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal
8.5.2 CF_TDOTS Command
Command
“CF_TDOTS_%1” [CR]
%1
“mmmm - nnnn” --------------- Directly specify setting value of Total Dots
“mmmm” indicates minimum value, which is current (Display area H + Position H) value
“nnnn” indicates maximum value, which is
less than 140 MHz in Dot Clocks
“UP” ------------------------- Increment setting value of Total Dots by 1
“DN” ------------------------- Decrement setting value of Total Dots by 1
Details
Set value of Total Dots in PC signal (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting.
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal
8.5.3 CF_CLPPHASE Command
Command
“CF_CLPPHASE_%1” [CR]
%1
“0000-0255” ----------- Directly specify setting value of Clamp Phase
“UP” --------------------- Increment setting value of Clamp Phase by 1
“DN” --------------------- Decrement setting value of Clamp Phase by 1
Details
Set value of Clamp Phase (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector. Therefore, when
the power is turned to ALL OFF, the value returns to the original setting.
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal