Sanyo PLC-ZM5000L RS232C Expand - Page 19

Image Command, 4.1 CF_ BRIGHT Command, 4.2 CF_CONT Command, 4.3 CF_COLOR Command, 4.4 CF_TINT

Page 19 highlights

PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ BRIGHT Command Command "CF_BRIGHT_%1" [CR] "000-063 Directly specify setting value of Brightness %1 "UP Increment setting value of Brightness by 1 "DN Decrement setting value of Brightness by 1 Details Set user controlled value of Brightness (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.4.2 CF_CONT Command Command "CF_CONT_%1" [CR] "000-063 Directly specify setting value of Contrast %1 "UP Increment setting value of Contrast by 1 "DN Decrement setting value of Contrast by 1 Details Set user controlled value of Contrast (Available only in the normal Power ON status) The value set by this command will not be stored in the projector. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.4.3 CF_COLOR Command Command "CF_COLOR_%1" [CR] "000-063 Directly specify setting value of Color %1 "UP Increment setting value of Color by 1 "DN Decrement setting value of Color by 1 Details Set user controlled value of Color (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.4.4 CF_TINT Command Command "CF_TINT_%1" [CR] "000-063 Directly specify setting value of Tint %1 "UP Increment setting value of Tint by 1 "DN Decrement setting value of Tint by 1 Details Set Tint value (Available only in the normal Power ON status) The value set by this command will not be saved to the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 19/89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
19/89
8.4
Image Command
8.4.1 CF_ BRIGHT Command
Command
“CF_BRIGHT_%1” [CR]
%1
“000-063”--------------- Directly specify setting value of Brightness
“UP”--------------------- Increment setting value of Brightness by 1
“DN”--------------------- Decrement setting value of Brightness by 1
Details
Set user controlled value of Brightness (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.2 CF_CONT Command
Command
“CF_CONT_%1” [CR]
%1
“000-063”--------------- Directly specify setting value of Contrast
“UP”--------------------- Increment setting value of Contrast by 1
“DN”--------------------- Decrement setting value of Contrast by 1
Details
Set user controlled value of Contrast (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector. Therefore, when
the power is turned to ALL OFF status, the value returns to the original setting. (It
is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.3 CF_COLOR Command
Command
“CF_COLOR_%1” [CR]
%1
“000-063”--------------- Directly specify setting value of Color
“UP”--------------------- Increment setting value of Color by 1
“DN”--------------------- Decrement setting value of Color by 1
Details
Set user controlled value of Color (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.4 CF_TINT Command
Command
“CF_TINT_%1” [CR]
%1
“000-063”--------------- Directly specify setting value of Tint
“UP”--------------------- Increment setting value of Tint by 1
“DN”--------------------- Decrement setting value of Tint by 1
Details
Set Tint value (Available only in the normal Power ON status)
The value set by this command will not be saved to the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]