LiftMaster CAPAC Installation Manual - English French Spanish - Page 6
Electrical Specifications, Storage and Shipping
View all LiftMaster CAPAC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
INTRODUCTION PRE-INSTALL NETWORK MOUNTING/POWER ACCESS CONTROL Electrical Specifications CAPAC SPECIFICATIONS CAPAC Capacity Supply Voltage Operating Current CAPAC Operating Temperature Range Enclosure Storage and Shipping Temperature Range Wiegand Outputs (2) 2 Relay Outputs Network Compatibility Wi-Fi® Compatibility Wi-Fi® Security Wi-Fi® Range Resident Capacity 50,000 (cloud only) 6-24VDC 0.7A (max at 7.5VDC, 0.2A max at 24VDC) -29°C to 65°C (-20°F to 149°F) ABS Plastic -40°C to 65°C (-40°F to 149°F) 26-bit, 30-bit, 32-bit, 37-bit SPDT, Rated Load - 2A at 30VDC (each) 10/100 Ethernet 802.11b/g/n WPA2 Personal (AES) and WPA3 Personal Up to 250 feet (76.2 m), Open Air/Line-of-Sight to CAPAC (range will vary depending on obstructions) 6
6
ACCESS CONTROL
MOUNTING/POWER
NETWORK
PRE-INSTALL
INTRODUCTION
Electrical Specifications
CAPAC SPECIFICATIONS
CAPAC Capacity
Resident Capacity 50,000 (cloud only)
Supply Voltage
6-24VDC
Operating Current
0.7A (max at 7.5VDC, 0.2A max at 24VDC)
CAPAC Operating
Temperature Range
-29°C to 65°C (-20°F to 149°F)
Enclosure
ABS Plastic
Storage and Shipping
Temperature Range
-40°C to 65°C (-40°F to 149°F)
Wiegand Outputs (2)
26-bit, 30-bit, 32-bit, 37-bit
2 Relay Outputs
SPDT, Rated Load - 2A at 30VDC (each)
Network Compatibility
10/100 Ethernet
Wi-Fi
®
Compatibility
802.11b/g/n
Wi-Fi
®
Security
WPA2 Personal (AES) and WPA3 Personal
Wi-Fi
®
Range
Up to 250 feet (76.2 m), Open Air/Line-of-Sight to CAPAC (range will vary depending on obstructions)