LiftMaster CAPAC Installation Manual - English French Spanish - Page 5

Overview, INPUT/OUTPUT, USED FOR, Relay Output 1, Wiegand Output 1, Input 1

Page 5 highlights

INTRODUCTION PRE-INSTALL Overview NETWORK MOUNTING/POWER ACCESS CONTROL Reset/Learn Button (back) LED Status Indicators External Antennas OUTPUT WIEGAND INPUT Mounting Location GATE 1 OUTPUT 2 SDA SCL NO COM NC NO COM NC 1 WIEGAND 2 D1 COM D0 D1 COM D0 INPUT POWER 1 GND 2 GND 12V-24V POWER ETHERNET Ethernet Port Power Adapter Port Mounting Location INPUT/OUTPUT Relay Output 1 Relay Output 2 Wiegand Output 1 Wiegand Output 2 Input 1 Input 2 USED FOR Gate Operator, Door Strikes, Maglocks, Lights (For control only. Power to be provided by external power supply), Alarm Shunt 26-bit, 30-bit, 32-bit, 37-bit Closed Door Sensor (Supervised EOL or unsupervised), Closed Limit Gate Sensor (Supervised EOL or unsupervised), Open Limit Gate Sensor (Supervised EOL or unsupervised) NOTE: For UL installations, only UL 325 Listed gate operators, UL 294 Listed electric door strikes or UL 294 Listed maglocks may be connected to relay output 1 or 2. NOTE: For UL installations, only a Listed UL 294 access control unit may be connected to Wiegand output 1 or 2. NOTE: The inputs can be used as a door sensor which will help detect the door ajar. The inputs can also be used for detecting close limit reached and open limit reached. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

5
ACCESS CONTROL
MOUNTING/POWER
NETWORK
PRE-INSTALL
INTRODUCTION
INPUT
OUTPUT
WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC
NO COM NC
1
2
D1 COM D0
D1 COM D0
1
2
WIEGAND
1
GND
2
INPUT
GND 12V-24V
POWER
POWER
ETHERNET
Overview
INPUT/OUTPUT
USED FOR
Relay Output 1
Gate Operator, Door Strikes, Maglocks, Lights (For control only. Power
to be provided by external power supply), Alarm Shunt
Relay Output 2
Wiegand Output 1
26-bit, 30-bit, 32-bit, 37-bit
Wiegand Output 2
Input 1
Closed Door Sensor (Supervised EOL or unsupervised),
Closed Limit Gate Sensor (Supervised EOL or unsupervised),
Open Limit Gate Sensor (Supervised EOL or unsupervised)
Input 2
Ethernet Port
Power Adapter Port
Mounting Location
Mounting Location
LED Status Indicators
Reset/Learn Button (back)
External Antennas
NOTE
: For UL installations, only UL 325 Listed gate operators, UL 294 Listed electric door strikes or
UL 294 Listed maglocks may be connected to relay output 1 or 2.
NOTE
: For UL installations, only a Listed UL 294 access control unit may be connected to Wiegand
output 1 or 2.
NOTE
: The inputs can be used as a door sensor which will help detect the door ajar.
The inputs can
also be used for detecting close limit reached and open limit reached.