LiftMaster CAPAC Installation Manual - English French Spanish - Page 16

Door Access, Auxiliary Relay, Primary Relay, Supervised Door Status

Page 16 highlights

INTRODUCTION PRE-INSTALL Door Access NETWORK MOUNTING/POWER ACCESS CONTROL PRE-INSTALL DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so may cause interference with the operation of panic hardware. Not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes. The information is for suggested use ONLY. Check your local codes BEFORE installation. OUTPUT WIEGAND INPUT GATE 1 OUTPUT 2 SDA SCL NO COM NC NO COM NC 1 WIEGAND 2 D1 COM D0 D1 COM D0 INPUT POWER 1 GND 2 GND 12V-24V POWER ETHERNET *PRIMARY RELAY For AC Power: DOOR STRIKE Install a Siemens S10K30MOV (Metal Oxide Varistor) (provided) or equivalent Power for Door Strike (Not Provided) Use 18-22 AWG COMMON + - - For DC Power: Install a 1N4005 diode or equivalent OR MAGLOCK NORMALLY OPEN For AC Power: Install a Siemens S10K30MOV (Metal Oxide Varistor) (provided) or equivalent Use 18-22 AWG NORMALLY CLOSED For DC Power: Install a 1N4005 diode or equivalent COMMON + Power for Maglock (Not Provided) DO NOT use the power supply for the controller 16 NORMALLY OPEN COMMON SUPERVISED (DOOR STATUS) DOOR SENSOR (NON-SUPERVISED) OR DOOR SENSOR (SUPERVISED) EOL (End of Line) Resistor (1k ohm) AUXILIARY RELAY Low Voltage Power Supply Isolation Relay LIGHT LOAD LINE OR ALARM BYPASS COMMON NORMALLY OPEN NEUTRAL NOTE: For UL installations, only UL 294 Listed electric door strikes or UL 294 Listed maglocks may be connected to relay output 1 or 2.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

16
ACCESS CONTROL
PRE-INSTALL
MOUNTING/POWER
NETWORK
PRE-INSTALL
INTRODUCTION
Door Access
INPUT
OUTPUT
WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC
NO COM NC
1
2
D1 COM D0
D1 COM D0
1
2
WIEGAND
1
GND
2
INPUT
GND 12V-24V
POWER
POWER
ETHERNET
COMMON
NORMALLY OPEN
ALARM BYPASS
LIGHT
NORMALLY OPEN
COMMON
LOAD
LINE
AUXILIARY RELAY
OR
NEUTRAL
Isolation
Relay
Low
Voltage
Power
Supply
+
+
DOOR STRIKE
MAGLOCK
For DC Power:
Install a 1N4005
diode or equivalent
Use 18-22 AWG
Power for Maglock
(Not Provided)
DO NOT
use the power
supply for the controller
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
Power for Door Strike
(Not Provided)
NORMALLY OPEN
COMMON
NORMALLY CLOSED
COMMON
OR
*PRIMARY RELAY
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
(provided) or equivalent
DOOR SENSOR
(SUPERVISED)
DOOR SENSOR
(NON-SUPERVISED)
OR
EOL (End of Line) Resistor
(1k ohm)
SUPERVISED (DOOR STATUS)
Not responsible for conflicts between the information listed in
the wiring diagram and the requirements of your local building
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE
UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING
JURISDICTION. Doing so may cause interference with the
operation of panic hardware.
NOTE
: For UL
installations, only UL
294 Listed electric
door strikes or UL
294 Listed maglocks
may be connected to
relay output 1 or 2.