Konica Minolta AccurioPress C6100 AccurioPress C6100/C6085 User Manual Additio - Page 33
Auto Inspection Unit UK-301, Relay Unit RU-510
View all Konica Minolta AccurioPress C6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
5 5.3.4 Output Option Specifications 5.3 Auto Inspection Unit UK-301 Type Function Paper size Supported paper type Paper weight System memory Local memory HDD Interface Dimensions Weight Power source Maximum power consumption Operating temperature Humidity Image analysis processing unit Image analysis Analyzes the image read by Intelligent Quality Optimizer IQ501, and detects an image failure. Report creation Creates a report of image analysis results. Conforms to Intelligent Quality Optimizer IQ-501. However, inspection is not possible for 487.8 mm / 19.2" or more. Conforms to the machine. However, it is not possible to inspect the following paper. PrePrinted, Label paper, Textured paper, Transparency, Tab paper, Envelope, NCR paper Conforms to Relay Unit RU-702. 16 GB 2 GB 4 TB (1 TB e 4) RJ45 Ethernet connector e 2 USB3.0 TypeA e 2 370 mm (W) e 559 mm (D) e 153 mm (H) / 14.57" (W) e 22.00" (D) e 6.02" (H) * Excluding the mounting plate and projections 11.2 kg / 24.69 lb AC100 to 240V (Supplied from the power cord.) 400 W or less 10 to 30°C 10 to 80%RH (No dew condensation) 5.3.5 Relay Unit RU-510 User's guide / Correction position