WASTE XPRESS TROUBLESHOOTING, Troubleshooting
![]() |
View all InSinkErator Model WX-300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Troubleshooting WASTE XPRESS TROUBLESHOOTING PROBLEM Auger runs in Counterclockwise (CCW) direction. POSSIBLE CAUSE • Power to auger motor reversed. SOLUTION • Reverse motor leads to auger motor or switch L1 and L2 connections on WX terminal block. Auger must run in Clockwise direction. Unit does not shut off with cover off • Waste Xpress Interlock not of Waste Xpress unit. operating properly. • Check interlock switch #3 and #95 connections on WX-101A to WX. • Call service Hot Water Spray is cold. Hot Water spray does not work. • Incorrectly plumbed. • No hot water. • Incorrectly wired. • Connect solenoid on WX unit to hot water source. • Ensure hot water heater/source is functioning. • Check connections on WX-101A #7 to WX #18. Auger reverses direction on each re-start. Waste Xpress unit will not start. • Waste Xpress unit auger motor has been wired into disposer motor circuit. • Incorrect wiring. • Re-wire as shown in instructions. • Check wiring. • Misaligned Interlock switch on chute. • Check chute for tight fit. Water Shuts off when unit shuts off. • Improper dipswitch setting (circuit board). • Refer to Page 14 to refer to dipswitch setting instructions. If the Waste Xpress remains inoperative after following this troubleshooting guide, contact InSinkErator's service department at 1-800-845-8345 for the location of the nearest approved service agency. 21