InSinkErator Model WX-300 Owners Manual - Page 16
Cleaning Instructions
View all InSinkErator Model WX-300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Cleaning Instructions PERSONAL INJURY Wait until auger paddles stop before cleaning Waste Xpress. 1. Press stop button on control center to stop system (disposer & Waste Xpress). 2. Holding both handles remove discharge chute by tilting it upward (see Figure 25). 3. Remove auger-bearing bracket by sliding the two captive fasteners inward and then pull bracket upward (see Figure 26 and 27). 4. Lift auger and screen up and then out (see Figure 26). 5. Remove auger from screen by lifting it up and out (see Figure 28). 6. Rinse auger, screen, auger compartment and discharge chute. Auger, screen and discharge chute are dishwasher safe and should be washed daily. Flush inlet and outlet with a fresh water supply to keep the drain lines clean. 7. Install auger into screen then place screen over drive. 8. Ensure that the auger drops into position. 9. Secure bearing bracket with captive fasteners. 10. Install discharge chute by placing bottom, front portion in first and then tilting back and downward. Discharge Chute Figure 25. Auger Screen Figure 26. Captive Fasteners Figure 27. Bearing Bracket Figure 28. 17