InSinkErator Model WX-300 Owners Manual - Page 16

Cleaning Instructions

Page 16 highlights

Cleaning Instructions PERSONAL INJURY Wait until auger paddles stop before cleaning Waste Xpress. 1. Press stop button on control center to stop system (disposer & Waste Xpress). 2. Holding both handles remove discharge chute by tilting it upward (see Figure 25). 3. Remove auger-bearing bracket by sliding the two captive fasteners inward and then pull bracket upward (see Figure 26 and 27). 4. Lift auger and screen up and then out (see Figure 26). 5. Remove auger from screen by lifting it up and out (see Figure 28). 6. Rinse auger, screen, auger compartment and discharge chute. Auger, screen and discharge chute are dishwasher safe and should be washed daily. Flush inlet and outlet with a fresh water supply to keep the drain lines clean. 7. Install auger into screen then place screen over drive. 8. Ensure that the auger drops into position. 9. Secure bearing bracket with captive fasteners. 10. Install discharge chute by placing bottom, front portion in first and then tilting back and downward. Discharge Chute Figure 25. Auger Screen Figure 26. Captive Fasteners Figure 27. Bearing Bracket Figure 28. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

17
PERSONAL INJURY
Wait until auger paddles stop before cleaning
Waste Xpress.
1.
Press stop button on control center to stop system
(disposer & Waste Xpress).
2.
Holding both handles remove discharge chute by
tilting it upward (see Figure 25).
3.
Remove auger-bearing bracket by sliding the two
captive fasteners inward and then pull bracket
upward (see Figure 26 and 27).
4.
Lift auger and screen up and then out
(see Figure 26).
5.
Remove auger from screen by lifting it up and out
(see Figure 28).
6.
Rinse auger, screen, auger compartment and
discharge chute. Auger, screen and discharge
chute are dishwasher safe and should be washed
daily. Flush inlet and outlet with a fresh water
supply to keep the drain lines clean.
7.
Install auger into screen then place screen
over drive.
8.
Ensure that the auger drops into position.
9.
Secure bearing bracket with captive fasteners.
10. Install discharge chute by placing bottom, front
portion in first and then tilting back and downward.
Figure 25.
Figure 26.
Figure 27. Bearing Bracket
Figure 28.
Cleaning Instructions
Discharge
Chute
Auger Screen
Captive
Fasteners