Icom IC-705 Ci-v Reference Guide english - Page 29

Scope span settings (in the Center mode and SCROLL-C mode Scope), Scope Reference level settings

Page 29 highlights

REMOTE CONTROL Remote control (CI-V) information DDCommand formats 6: Out of range information: •• 00 = In range •• 01 = Out of range LLIf the scope data is out of range, the waveform data (7) is omitted. 7: Waveform data: The transceiver outputs the drawn waveform data. The data range or data length of the waveform data is judged by the controller. (The data range is basically the same as the display size of the scope on the controller.) •• Data range: 0 ~ 160 •• Data length: 475 0 (Fixed) 0 (Fixed) 10 Hz digit: 0 (Fixed) 1 Hz digit: 0 (Fixed) 1 kHz digit: 0, 2, 5 100 Hz digit: 0, 5 100 kHz digit: 0, 1, 2, 5 10 kHz digit: 0, 1, 2, 5 10 MHz digit: 0 (Fixed) 1 MHz digit: 0 (Fixed) 1 GHz digit: 0 (Fixed) 100 MHz digit: 0 (Fixed) •• Scope span settings (in the Center mode and SCROLL-C mode Scope) Command: 27 15 123 456 0 0 0 0XX XX 0 00 0 Span (kHz) 2500 2.5 5000 5 10000 10 25000 25 50000 50 100000 100 250000 250 500000 500 •• Scope Reference level settings Command: 27 19 XX XX X0 XX 00= + (plus) 01= - (minus) •• Scope Fixed edge frequency settings Command: 27 1E 1 2 3 4 5 6 7 8 9 10 11 12 X X0X X X XX X X XX 0 XX X X X X X X X 0X Frequency range Edge number: 01 ~ 04 10 Hz digit: 0 ~ 9 1 Hz digit: 0 ~ 9 1 kHz digit: 0 ~ 9 100 Hz digit: 0 ~ 9 100 kHz digit: 0 ~ 9 10 kHz digit: 0 ~ 9 10 MHz digit: 0 ~ 9 1 MHz digit: 0 ~ 9 1 GHz digit: 0 (Fixed) 100 MHz digit: 0 ~ 4 10 Hz digit: 0 ~ 9 1 Hz digit: 0 ~ 9 1 kHz digit: 0 ~ 9 100 Hz digit: 0 ~ 9 100 kHz digit: 0 ~ 9 10 kHz digit: 0 ~ 9 10 MHz digit: 0 ~ 9 1 MHz digit: 0 ~ 9 1 GHz digit: 0 (Fixed) 100 MHz digit: 0 ~ 4 Lower edge Higher edge LLEntry of less than 1 kHz digits are ignored. 1 Selectable Frequency ranges: Data 01 Frequency range (Hz) 0.03 ~ 1.60 02 1.60 ~ 2.00 03 2.00 ~ 6.00 04 6.00 ~ 8.00 05 8.00 ~ 11.00 06 11.00 ~ 15.00 07 15.00 ~ 20.00 08 20.00 ~ 22.00 09 22.00 ~ 26.00 10 26.00 ~ 30.00 11 30.00 ~ 45.00 12 45.00 ~ 60.00 13 60.00 ~ 74.80 14 74.80 ~ 108.00 15 108.00 ~ 137.00 16 137.00 ~ 200.00 17 400.00 ~ 470.00 2 Selectable Edge number: 01=1, 02=2, 03=3, 04=4 0 (Fixed) 0 (Fixed) 10 dB digit: 0, 1, 2 1 dB digit: 0 ~ 9 0�1 dB digit: 0, 5 0�01 dB digit: 0 (Fixed) Adjustable range: -20.0 dB ~ +20.0 dB in 0.5 dB steps. 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

28
REMOTE CONTROL
Remote control (CI-V) information
D
Command formats
Scope span settings
(in the Center mode and SCROLL-C mode Scope)
Command: 27 15
0
0
0
0XX
XX
0
00
0
1
1 kHz digit: 0, 2, 5
100 Hz digit: 0, 5
100 kHz digit: 0, 1, 2, 5
10 kHz digit: 0, 1, 2, 5
10 Hz digit: 0 (Fixed)
1 Hz digit: 0 (Fixed)
10 MHz digit: 0 (Fixed)
1 MHz digit: 0 (Fixed)
1 GHz digit: 0 (Fixed)
100 MHz digit: 0 (Fixed)
2
3
4
5
6
0 (Fixed)
0 (Fixed)
Span (kHz)
2500
2�5
5000
5
10000
10
25000
25
50000
50
100000
100
250000
250
500000
500
Scope Reference level settings
Command: 27 19
X
X
XX
X
0
XX
00= + (plus)
01= – (minus)
10 dB digit: 0, 1, 2
1 dB digit: 0
~
9
0�1 dB digit: 0, 5
0�01 dB digit: 0
(Fixed)
0 (Fixed)
0 (Fixed)
Adjustable range: –20�0 dB ~ +20�0 dB
in 0�5 dB steps�
6
: Out of range information:
00 = In range
01 = Out of range
L
If the scope data is out of range, the waveform
data (
¹
) is omitted�
¹
: Waveform data:
The transceiver outputs the drawn waveform data�
The data range or data length of the waveform
data is judged by the controller� (The data range is
basically the same as the display size of the scope
on the controller�)
Data range: 0 ~ 160
Data length: 475
Scope Fixed edge frequency settings
Command: 27 1E
1
0X
XX
X
2
3
4
5
6
·
¸
¹
*
+
;
XX
XX
XX
X0
X
X
XX
XX
XX
X0
X
10 Hz digit: 0
~
9
1 Hz digit: 0
~
9
1 kHz digit: 0
~
9
100 Hz digit: 0
~
9
100 kHz digit: 0
~
9
10 kHz digit: 0
~
9
10 MHz digit: 0
~
9
1 MHz digit: 0
~
9
1 GHz digit: 0
(Fixed)
100 MHz digit: 0
~
4
10 Hz digit: 0
~
9
1 Hz digit: 0
~
9
1 kHz digit: 0
~
9
100 Hz digit: 0
~
9
100 kHz digit: 0
~
9
10 kHz digit: 0
~
9
10 MHz digit: 0
~
9
1 MHz digit: 0
~
9
1 GHz digit: 0
(Fixed)
100 MHz digit: 0
~
4
Frequency range
Lower edge
Higher edge
Edge number: 01
~
04
L
Entry of less than 1 kHz digits are ignored�
1
Selectable Frequency ranges:
Data
Frequency range (Hz)
01
0�03 ~
1�60
02
1�60 ~
2�00
03
2�00 ~
6�00
04
6�00 ~
8�00
05
8�00 ~ 11�00
06
11�00 ~ 15�00
07
15�00 ~ 20�00
08
20�00 ~ 22�00
09
22�00 ~ 26�00
10
26�00 ~ 30�00
11
30�00 ~ 45�00
12
45�00 ~ 60�00
13
60�00 ~ 74�80
14
74�80 ~ 108�00
15
108�00 ~ 137�00
16
137�00 ~ 200�00
17
400�00 ~ 470�00
2
Selectable Edge number: 01=1, 02=2, 03=3, 04=4