Icom IC-705 Ci-v Reference Guide english - Page 24
DV Digital code squelch setting, DV MY call sign setting, DV TX call signs setting (24 characters)
View all Icom IC-705 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• DV Digital code squelch setting Command: 1 B 07 1 XX •• DV RX call sign data Command: 20 0001, 0002 1, 2 3 ~ 10 11 ~ 14 15 ~ 22 X X X X X X X X X X X X X X X X First digit: 0 ~ 9 Second digit: 0 ~ 9 •• DV MY call sign setting Command: 1 F 00 Set your own call sign and note of up to 12 characters. See "Character's code of the call sign." 1 ~ 8 9 ~ 12 X X X X X X X X X X X X 1 ~ 8: Your own call sign setting (8 characters) 9 ~ 12: Note setting (4 characters) •• DV TX call signs setting (24 characters) Command: 1 F 01 Set "UR," "R1," and "R2" call signs of 8 characters (fixed). See "Character's code of the call sign." 1 ~ 8 9 ~ 16 17 ~ 24 X X X X X X X X X X X X 1 ~ 8: U R (Destination) call sign setting (8 characters) 9 ~ 16: R 1 (Access/Area repeater) call sign setting (8 characters) 17 ~ 24: R 2 (Link/Gateway repeater) call sign setting (8 characters) Character's code of the call sign Character ASCII code 0 ~ 9 30 ~ 39 A ~ Z 41 ~ 5A (Space) 20 / 2F •• DV TX message setting Command: 1 F 02 Set the transmit message of up to 20 characters. See "Codes for character entries." (p. 19) "FF" stops sending or reading messages. 23 ~ 30 31 ~ 38 X X X X X X X X 1: Header flag data (First byte) Data bit7 (0: Fixed) bit6 (0: Fixed) bit5 (0: Fixed) Description - - - bit4 0/1 0=Voice, 1=Data bit3 0/1 0=Direct, 1=Through repeater bit2 0/1 0=No Break-in, 1=Break-in bit1 0/1 0=Data, 1=Control bit0 0/1 0=Normal, 1=EMR 2: Header flag data (Second byte) Data bit2 bit1 bit0 Description 1 1 1 Repeater control 1 1 0 Send auto acknowledge 1 0 1 (Not used) 1 0 0 Request to re-transmit 0 1 1 Send acknowledge 0 1 0 Receive no reply 0 0 1 Repeater disabled 0 0 0 NULL 3 ~ 10: C all sign of the caller station (8 characters, fixed) 11 ~ 14: N ote of the caller station (4 characters, fixed) 15 ~ 22: C all sign of the called station (8 characters, fixed) 23 ~ 30: C all sign of the access/area repeater (R1) (8 characters, fixed) 31 ~ 38: C all sign of the link/gateway repeater (R2) (8 characters, fixed) See "Codes for character entries." (p. 19) LLFF: W hen no call sign is received since the transceiver power was turned ON. 23