- Icom IC-705 | Ci-v Reference Guide english - Page 1
CI-V REFERENCE GUIDE HF/VHF/UHF ALL MODE TRANSCEIVER |705 - Icom IC-705 | Ci-v Reference Guide english - Page 2
Key setting 21 •• Color settings 21 •• Bandscope edge frequency settings 21 •• [VOX/BK-IN] setting 21 •• [AUTOTUNE/RX>CS] setting 22 •• Manually entered position data 22 •• D-PRS Symbol setting 22 •• Alarm area (Group) setting 22 •• Data mode with filter width settings 22 •• Repeater tone - Icom IC-705 | Ci-v Reference Guide english - Page 3
.icomjapan.com/support/ DDPreparing The Icom Communications Interface V (CI-V) is used for remote control. To control the transceiver, first set its address, data communication speed, and transceive function. These settings are set in the Set mode (Refer to the IC-705 instruction manual). DDAbout - Icom IC-705 | Ci-v Reference Guide english - Page 4
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data 00 See p. 17. 01 02*1 03*1 04*1 05*2 06*2 07 00 01 A0 See p. 17. See p. 17. See p. 17. See p. 17. See p. 17. See p. 17. B0 08*2 0000 ~ 0099 A0 0000 ~ 0100 09 0A 0B 0C*1 0D*2 0E 00 01 02 03 12 13 22 23 - Icom IC-705 | Ci-v Reference Guide english - Page 5
-IN OFF, 01=Semi BK-IN ON, 02=Full BK-IN ON) Send/read the Manual Notch function (00=OFF, 01=ON) Send/read the DTCS function (00=OFF, 01= DSP IF filter type in the operating band (00=SHARP, 01=SOFT) Send/read the Manual Notch width (00=WIDE, 01=MID, 02=NAR) Send/read SSB transmit bandwidth (00=WIDE - Icom IC-705 | Ci-v Reference Guide english - Page 6
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data Description 19*1 00 Read the transceiver ID 1A* 00 See pp. 18 and 19. Send/read memory contents 01 See p. 19. Send/read band stacking register contents 02*5 See p. 20. Send/read memory keyer contents - Icom IC-705 | Ci-v Reference Guide english - Page 7
=Slow, 01=Fast) 0067 00 ~ 02 Send/read the [NOTCH] Switch (SSB) setting (00=Auto, 01=Manual, 02=Auto/Manual) 0068 00 ~ 02 Send/read the [NOTCH] Switch (AM) setting (00=Auto, 01=Manual, 02=Auto/Manual) 0069 00/01 Send/read the SSB/CW Synchronous Tuning setting (00=OFF, 01=ON) 0070 00 - Icom IC-705 | Ci-v Reference Guide english - Page 8
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data Description 1A* 05 SET > Function > Remote MIC Key 0078 00/01 Send/read the Mode Select (SSB) setting (00=OFF, 01=ON) 0079 00/01 Send/read the Mode Select (CW) setting (00=OFF, 01=ON) 0080 00/01 Send/read - Icom IC-705 | Ci-v Reference Guide english - Page 9
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data 1A* 05 SET > Connectors 0116 0000 ~ 0255 0117 0000 ~ 0255 0118 00 ~ 03 0119 00 ~ 03 0120 00/01 0121 00/01 0123 00/01 0124 00/01 0125 00 ~ 04 0126 00 ~ 04 0127 00 ~ 04 0128 00/01 Description MOD Input > - Icom IC-705 | Ci-v Reference Guide english - Page 10
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data 1A* 05 SET > Display 0145 00 ~ 03 0146 00/01 0147 00/01 0148 00 ~ 04 0149 00/01 0150 00/01 0151 00/01 0152 00 ~ 02 0153 00/01 0154 00/01 0155 00/01 0156 00 ~ 02 0157 00/01 0158 00 ~ 02 0159 00/01 0160 00 ~ - Icom IC-705 | Ci-v Reference Guide english - Page 11
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data Description 1A* 05 SCOPE > SCOPE SET 0184 00 ~ 02 Send/read the Waterfall Speed setting (00=Slow, 01=Mid, 02=Fast) 0185 00 ~ 02 Send/read the Waterfall Size (Expand Screen) setting (00=Small, 01=Mid, 02= - Icom IC-705 | Ci-v Reference Guide english - Page 12
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data Description 1A* 05 AUDIO > AUDIO SCOPE SET 0239 00/01 Send/read the FFT Scope Waveform Type setting (00=Line, 01=Fill) 0240 See p. 21. Send/read the FFT Scope Waveform Color setting 0241 00/01 Send/read - Icom IC-705 | Ci-v Reference Guide english - Page 13
~ 02 GPS Set > Send/read the GPS Select setting (00=OFF, 01=ON, 02=Manual) 0282 00/01 GPS Set > GPS Option > Send/read the SBAS setting (00=OFF /QZSS/GLONASS, 01=GPS Only) 0286 See p. 22. GPS Set > Send/read the Manual Position setting 0287 00 ~ 02 Send/read the GPS TX Mode setting (00=OFF, 01 - Icom IC-705 | Ci-v Reference Guide english - Page 14
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data Description 1A* 05 GPS > GPS TX Mode > D-PRS > TX Format > Item 0322 See p. 19. Send/read the Item Name setting (Up to 9 characters) 0323 00/01 Send/read the Data Type setting (00=Live Item, 01=Killed Item) - Icom IC-705 | Ci-v Reference Guide english - Page 15
Battery Pack Confirmation setting (00=OFF, 01=ON) SET > Function > Tuner 0365 00/01 Send/read the Tuner Select setting (00=AH-705, 01=Others) 0366 00/01 AH-705 > Send/read the Tune Memory setting (00=OFF, 01=ON) SET > Function > Front Key Customize 0367 See p. 21. Send/read the [VOX - Icom IC-705 | Ci-v Reference Guide english - Page 16
, 01=1sec ~ 10=10sec) Read the position status GPS > GPS Set > Send/read the GPS Select setting (00=OFF, 01=ON, 03=Manual) GPS > GPS Set > Send/read the Manual Position setting Send/read TX output power setting (00=OFF, 01=ON) Set the TX output power for transceive (00=OFF, 01 - Icom IC-705 | Ci-v Reference Guide english - Page 17
REMOTE CONTROL Remote control (CI-V) information DDCommand table Cmd. Sub cmd. Data 27* 17 0000/ 0001 19 See p. 28. 1A 0000 ~ 0002 1B 00/01 1C 00 ~ 02 1D 0000/ 0001 1E See p. 28. 20 00/01 28 00 00 ~ 08 Description Send/read the Scope hold function ON/OFF status (0000=OFF, - Icom IC-705 | Ci-v Reference Guide english - Page 18
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• Operating frequency Command: 00, 03, 05, 1C 03 1 XX 2 XX 3 XX 4 XX 5 0X •• Duplex Offset frequency setting Command: 0C, 0D q XX w XX e 0X 10 Hz digit: 0 ~ 9 1 Hz digit: 0 ~ 9 1 kHz digit: 0 ~ 9 100 Hz digit: 0 ~ 9 100 - Icom IC-705 | Ci-v Reference Guide english - Page 19
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• Memory content Command: 1A 00 1, 2 3, 4 5 6~ 10 11 12 13 14 15 16 ~ 18 19 ~ 21 22 ~ 24 X X X X X X X X X X X X ...... X X X X X X X X X X X 0 X X X X X X X X X X X X X X X X X X 25 26 ~28 29~36 37 ~ 44 45 ~ 52 6 ~ - Icom IC-705 | Ci-v Reference Guide english - Page 20
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• Codes for character entries Command: 1A 00, 1A 05 0168, 0288, 0308, 0310, 0311, 0322, 0325, 0337, 0345, 1A 05 0291 ~ 1A 05 0294, 1A 05 0297 ~ 1A 05 0300 - Character codes- Letters and Numbers Character A ~ Z 0 - Icom IC-705 | Ci-v Reference Guide english - Page 21
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• Keyer memory character entries Command: 1A 02 - Character codes Character ASCII code Description 0 ~ 9 30 ~ 39 Numbers A ~ Z 41 ~ 5A Letters Space 20 Word space / 2F Symbol ? 3F Symbol , 2C Symbol . 2E - Icom IC-705 | Ci-v Reference Guide english - Page 22
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• UTC Offset setting Command: 1A 05 0170 XXXXXX Offset time 0000 ~ 1400 Shift direction 00=+ (plus) 01=− (minus) •• Remote MIC Key setting Command: 1A 05 0074 ~ 1A 05 0077 Data Function 00 No function 01 UP 02 DOWN 03 - Icom IC-705 | Ci-v Reference Guide english - Page 23
1 2 3 XX X X X 0 10 min� digit: 0 ~ 5 1 min� digit: 0 ~ 9 0�1 min� digit: 0 ~ 9 0�01 min� digit: 0 ~ 9 0�001 min� digit: 0 ~ 9 0 (fixed) •• Manually entered position data Command: 1 A 05 0286, 0312, 0326, 23 02 1 ~ 5 6 ~ 11 12 ~ 15 X X X X X X X X X X X X 1 2 3 4 5 6 7 8 9 10 11 12* 13 - Icom IC-705 | Ci-v Reference Guide english - Page 24
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• DV Digital code squelch setting Command: 1 B 07 1 XX •• DV RX call sign data Command: 20 0001, 0002 1, 2 3 ~ 10 11 ~ 14 15 ~ 22 X X X X X X X X X X X X X X X X First digit: 0 ~ 9 Second digit: 0 ~ 9 •• DV MY call - Icom IC-705 | Ci-v Reference Guide english - Page 25
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• DV RX message Command: 2 0 0101, 0102 1 ~ 20 21 ~ 28 29 ~ 32 •• GPS/D-PRS data Command: 20 03 0100, 0101, 0102, 0103, 0200, 0201, 0202, 0203 X X X X X X X X X X X X Data number and description 1 ~ 20: Message (20 - Icom IC-705 | Ci-v Reference Guide english - Page 26
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• GPS/D-PRS data (Continued) Object Command: 20 03 0101, 0201 1 ~ 9 10 11 12 ~ 16 0 1 X X X X X X X X X X X X Data number 17 ~ 22 23 ~ 26 27 28 X X X X X X X X X X X X Item Command: 20 03 0102, 0202 1 ~ 9 10 11 - Icom IC-705 | Ci-v Reference Guide english - Page 27
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• GPS/D-PRS data (Continued) Weather Command: 20 03 0103, 0203 •• RIT frequency settings Command: 21 00 X X X X XX 10 Hz: 0 ~ 9 1 Hz: 0 ~ 9 1 kHz: 0 ~ 9 100 Hz: 0 ~ 9 1 ~ 9 10 11 12 ~ 16 0 3 X X X X X X X X X X X X - Icom IC-705 | Ci-v Reference Guide english - Page 28
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• Selected or unselected VFO frequency settings Command: 25 XXXXXX XXXXXX 00=Selected VFO 01=Unselected VFO Operating frequency See "Operating frequency." (p. 17) LLWhen using the DR function, the transceiver returns "FA" (NG) - Icom IC-705 | Ci-v Reference Guide english - Page 29
REMOTE CONTROL Remote control (CI-V) information DDCommand formats 6: Out of range information: •• 00 = In range •• 01 = Out of range LLIf the scope data is out of range, the waveform data (7) is omitted. 7: Waveform data: The transceiver outputs the drawn waveform data. The data range or data - Icom IC-705 | Ci-v Reference Guide english - Page 30