Adaptec FS4500 User Guide - Page 60
Fibre Channel ID Assignment, Disk Drive ID Map
UPC - 760884144275
View all Adaptec FS4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
Fibre Channel Storage Enclosures (FC4100) Fibre Channel ID Assignment Each FC drive slot has a unique ID assigned to it. The IDs are assigned by a combination of slot number and enclosure ID. The slot numbers are pre-assigned, as shown in Figure 1-2 on page 1-5. You set the enclosure ID to any number between 0 and 9, using the ID switch on the ES module, shown in Figure 1-1 on page 1-4. When you power-on the enclosure, the ES module and LIO module read the ID switch setting and set the enclosure ID. If you change the enclosure ID, you must power cycle the enclosure before it will read the change. Disk Drive ID Map This table lists disk drive IDs by enclosure ID. If you change the enclosure ID, you must power cycle the enclosure before it will read the change and update the disk drive ID. Table 6-3 Loop Identifier Map Enclosure Disk Drive IDs by Drive Slot ID 12 11 10 9 8 7 6 5 4 3 2 1 0 11 10 9 8 7 6 5 4 3 2 1 0 1 27 26 25 24 23 22 21 20 19 18 17 16 2 43 42 41 40 39 38 37 36 35 34 33 32 3 59 58 57 56 55 54 53 52 51 50 49 48 4 75 74 73 72 71 70 69 68 67 66 65 64 5 91 90 89 88 87 86 85 84 83 82 81 80 6 107 106 105 104 103 102 101 100 99 98 97 96 7 123 122 121 120 119 118 117 116 115 114 113 112 6-5