Adaptec FS4500 User Guide - Page 33

About the ES Module, Silencing the Audible Alarm

Page 33 highlights

Monitoring About the ES Module The ES module, shown in Figure 3-1, is located on the rear of the Storage Enclosure, between the two APC modules. Yellow LED = ES/Alarm Fault ID Switch Green LED = ES/Alarm OK ES Module Figure 3-1 ES Module Alarm Mute Button The ES module receives and reports status information for the Storage Enclosure's APC modules, disk drives, and for the enclosure itself. The ES module receives and reports status through a two-wire serial bus that connects to the I/O module. It reports status using LEDs (on the APC modules, drive carriers, and enclosure) and an audible alarm. The ES module can also be used for downloading firmware. The ES module is hot-swappable, and removing it does not affect the data path. For more information, see Hot-swapping the ES Module on page 4-9. Silencing the Audible Alarm When an event occurs in the Storage Enclosure that triggers the audible alarm, you can turn off the alarm manually by pressing the Alarm Mute button on the ES module (shown in Figure 3-1.) Pressing the Alarm Mute button deactivates the alarm. The alarm remains deactivated until the ES module is reset or until another alarm occurs. Note: You can also silence the alarm using Adaptec Storage Examiner software. See the Installation and User's Guide on your Adaptec Storage Enclosure CD for detailed instructions. 3-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91

3-2
Monitoring
About the ES Module
The ES module, shown in
Figure 3-1
, is located on the rear of the
Storage Enclosure, between the two APC modules.
Figure 3-1
ES Module
The ES module receives and reports status information for the Storage
Enclosure’s APC modules, disk drives, and for the enclosure itself. The
ES module receives and reports status through a two-wire serial bus
that connects to the I/O module. It reports status using LEDs (on the
APC modules, drive carriers, and enclosure) and an audible alarm.
The ES module can also be used for downloading firmware.
The ES module is hot-swappable, and removing it does not affect
the data path. For more information, see
Hot-swapping the ES
Module
on page 4-9
.
Silencing the Audible Alarm
When an event occurs in the Storage Enclosure that triggers the
audible alarm, you can turn off the alarm manually by pressing the
Alarm Mute button on the ES module (shown in
Figure 3-1
.)
Pressing the Alarm Mute button deactivates the alarm. The alarm
remains deactivated until the ES module is reset or until another
alarm occurs.
Note:
You can also silence the alarm using Adaptec Storage
Examiner software. See the
Installation and User’s Guide
on
your Adaptec Storage Enclosure CD for detailed instructions.
Yellow LED = ES/Alarm Fault
ID Switch
Alarm Mute Button
ES Module
Green LED =
ES/Alarm OK