306 Chapter 7 - Color Workflow 5. Follow the Color Calibration Wizard steps. Note: Make sure you set the screen type to the one you are going to use to print the job-for example, 200 dot. 6. When you measure the two calibration charts, place them on the surface you prepared-for example, on top of the white paper. 7. When the calibration is complete, print the job using the calibration table, see Printing the Job with the Calibration Table on page 327. Tip: It is strongly recommended that you include the specific paper name and screen method in the calibration table file name. This helps you select the correct calibration table in the job setup. Calibrating the DTP32HS Densitometer The X-Rite DTP32HS densitometer is a "high speed"color measurement instrument that reports densitometer and dot data. Perform the following steps before first time use of the X-Rite DTP32HS densitometer: • Familiarize yourself with the X-Rite DTP32HS Densitometer Operator's Manual. You can also use the DTP32HS Tutorial to learn how to use the DTP 32HS densitometer correctly. Access the tutorial from Tools>Calibration, and then click Calibrate. In Step 1 of the Color Calibration wizard, click DTP32HS Tutorial - Click & Learn. • Connect the X-Rite DTP32HS Densitometer. • Calibrate the X-Rite DTP32HSDensitometer.