Page 68 highlights
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command "CR_PROJH" [CR] Details Get total running time of Projector (in hours) Response Acceptable %1 "000_%1" [CR] "0000000 - 0099999" Unacceptable "Error Code" [CR] 9.9.7 CR_HMLAMP Command Command "CR_HMLAMP" [CR] Details Get total lamp number Response Acceptable %1 "000_%1" [CR] "001" Unacceptable "Error Code" [CR] 9.9.8 CR_LAMPLIFECONTRL Command Command "CR_LAMPLIFECONTRL" [CR] Details Get setting status of Lamp life control Acceptable "000_%1" [CR] Response %1 "MODE1 Lamp life control is Mode1 status "MODE2 Lamp life control is Mode2 status Unacceptable "Error Code" [CR] 68/79
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications
68/79
9.9.6
CR_PROJH Command
Command
“CR_PROJH” [CR]
Details
Get total running time of Projector (in hours)
Acceptable
“000_%1” [CR]
%1
“0000000 – 0099999”
Response
Unacceptable
“Error Code” [CR]
9.9.7
CR_HMLAMP Command
Command
“CR_HMLAMP” [CR]
Details
Get total lamp number
Acceptable
“000_%1” [CR]
%1
“001”
Response
Unacceptable
“Error Code” [CR]
9.9.8
CR_LAMPLIFECONTRL Command
Command
“CR_LAMPLIFECONTRL” [CR]
Details
Get setting status of Lamp life control
Acceptable
“000_%1” [CR]
%1
“MODE1” --------------- Lamp life control is Mode1 status
“MODE2” --------------- Lamp life control is Mode2 status
Response
Unacceptable
“Error Code” [CR]