PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL" [CR] Details Get information of Lamp Replacement time Acceptable "000_%1" [CR] Response %1 "1Y indicates over lamp replacement time "1N indicates under lamp replacement time Unacceptable "?" [CR] 9.9.2 CR_LAMPH Command Command "CR_LAMPH" [CR] Details Get Lamp running time (in hours) * return actual lamp running time Response Acceptable %1 "000_%1" [CR] "00000 - 99999" Unacceptable "Error Code" [CR] 9.9.3 CR_LAMPCORRESPH Command Command "CR_LAMPCORRESPH" [CR] Details Get Lamp running time (in hours) *return lamp running time multiplied by a coefficient (not actual running time) Response Acceptable %1 "000_%1" [CR] "00000 - 99999" Unacceptable "Error Code" [CR] 9.9.4 CR_LAMPMODE Command Command "CR_LAMPMODE" [CR] Details Get setting status of Lamp mode Acceptable "000_%1" [CR] Response "NORMAL Lamp mode is Normal status %1 "ECO1 Lamp mode is Eco1 status "ECO2 Lamp mode is Eco2 status "AUTO Lamp mode is Auto status Unacceptable "?" [CR] 9.9.5 CR_LAMPSTS Command Command "CR_LAMPSTS" [CR] Details Get Lamp status Acceptable "000_%1" [CR] Response %1 "1I Lamp is ON "1O Lamp is OFF "1X Lamp Failure Unacceptable "Error Code" [CR] 67/79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications
67/79
9.9
Lamp Status Read Command
9.9.1
CR_LAMPREPL Command
Command
“CR_LAMPREPL” [CR]
Details
Get information of Lamp Replacement time
Acceptable
“000_%1” [CR]
%1
“1Y” ----------------- indicates over lamp replacement time
“1N” ----------------- indicates under lamp replacement time
Response
Unacceptable
“?” [CR]
9.9.2
CR_LAMPH Command
Command
“CR_LAMPH” [CR]
Details
Get Lamp running time (in hours)
* return actual lamp running time
Acceptable
“000_%1” [CR]
%1
“00000 - 99999”
Response
Unacceptable
“Error Code” [CR]
9.9.3
CR_LAMPCORRESPH Command
Command
“CR_LAMPCORRESPH” [CR]
Details
Get Lamp running time (in hours)
*return lamp running time multiplied by a coefficient (not actual running time)
Acceptable
“000_%1” [CR]
%1
“00000 – 99999”
Response
Unacceptable
“Error Code” [CR]
9.9.4
CR_LAMPMODE Command
Command
“CR_LAMPMODE” [CR]
Details
Get setting status of Lamp mode
Acceptable
“000_%1” [CR]
%1
“NORMAL” --------------- Lamp mode is Normal status
“ECO1” -------------------- Lamp mode is Eco1 status
“ECO2” -------------------- Lamp mode is Eco2 status
“AUTO” -------------------- Lamp mode is Auto status
Response
Unacceptable
“?” [CR]
9.9.5
CR_LAMPSTS Command
Command
“CR_LAMPSTS” [CR]
Details
Get Lamp status
Acceptable
“000_%1” [CR]
%1
“1I” ------------------------ Lamp is ON
“1O” ---------------------- Lamp is OFF
“1X” ----------------------- Lamp Failure
Response
Unacceptable
“Error Code” [CR]