PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.4.9 CR_WBAL-B Command Command "CR_WBAL-B" [CR] Details Get user controlled Blue value of White Balance Acceptable "000_%1" [CR] Response %1 "000 - 063" Unacceptable "Error Code" [CR] 9.4.10 CR_COLTEMP Command Command "CR_COLTEMP" [CR] Details Get Color Temperature setting status Acceptable "000_%1" [CR] "000 Xlow "001 Low Response %1 "002 Mid "003 High "BLANK" ---- OSD Menu is blank (Neither of Xlow / Low / Mid / High) Unacceptable "Error Code" [CR] 9.4.11 CR_OFFSET-R Command Command "CR_OFFSET-R" [CR] Details Get user controlled Red value of Offset Acceptable Response %1 "000_%1" [CR] "000 - 063" Unacceptable "Error Code" [CR] 9.4.12 CR_OFFSET-G Command Command "CR_OFFSET-G" [CR] Details Get user controlled Green value of Offset Response Acceptable %1 "000_%1" [CR] "000 - 063" Unacceptable "Error Code" [CR] 9.4.13 CR_OFFSET-B Command Command "CR_OFFSET-B" [CR] Details Get user controlled Blue value of Offset Response Acceptable %1 "000_%1" [CR] "000 - 063" Unacceptable "Error Code" [CR] 52/79