PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command "CR_HMSLOT" [CR] Details Get the total number of Input. Acceptable "000_%1" [CR] Response %1 "004 When PJ-Net is attached. "003 When PJ-Net is not attached. Unacceptable "Error Code" [CR] 9.7.11 CR_NMSLOT1 Command Command "CR_NMSLOT1" [CR] Details Get terminal information of Input1 Response Acceptable %1 "000_%1" [CR] "RGB" Unacceptable "Error Code" [CR] 9.7.12 CR_NMSLOT2 Command Command "CR_NMSLOT2" [CR] Details Get terminal information of Input2 Response Acceptable %1 "000_%1" [CR] "5BNC" Unacceptable "Error Code" [CR] 9.7.13 CR_NMSLOT3 Command Command "CR_NMSLOT3" [CR] Details Get terminal information of Input3 Acceptable "000_%1" [CR] Response %1 "VIDEO" Unacceptable "Error Code" [CR] 9.7.14 CR_NMSLOT4 Command Command "CR_NMSLOT4" [CR] Details Get terminal information of Input4 Acceptable "000_%1" [CR] Response "NETWORK" -------- When PJ-Net is attached. *With PJ-Net unattached, this command is invalid and error code "103" is returned. %1 *With PJ-Net attached and the power OFF, error code "101" is returned. *In models not supporting PJ-Net, error code "103" is returned. Unacceptable "Error Code" [CR] 63/79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications
63/79
9.7.10
CR_HMSLOT Command
Command
“CR_HMSLOT” [CR]
Details
Get the total number of Input.
Acceptable
“000_%1” [CR]
%1
“004” ------------ When PJ-Net is attached.
“003” ------------ When PJ-Net is not attached.
Response
Unacceptable
“Error Code” [CR]
9.7.11
CR_NMSLOT1 Command
Command
“CR_NMSLOT1” [CR]
Details
Get terminal information of Input1
Acceptable
“000_%1” [CR]
%1
“RGB”
Response
Unacceptable
“Error Code” [CR]
9.7.12
CR_NMSLOT2 Command
Command
“CR_NMSLOT2” [CR]
Details
Get terminal information of Input2
Acceptable
“000_%1” [CR]
%1
“5BNC”
Response
Unacceptable
“Error Code” [CR]
9.7.13
CR_NMSLOT3 Command
Command
“CR_NMSLOT3” [CR]
Details
Get terminal information of Input3
Acceptable
“000_%1” [CR]
%1
“VIDEO”
Response
Unacceptable
“Error Code” [CR]
9.7.14
CR_NMSLOT4 Command
Command
“CR_NMSLOT4” [CR]
Details
Get terminal information of Input4
Acceptable
“000_%1” [CR]
%1
“NETWORK” -------- When PJ-Net is attached.
*With PJ-Net unattached, this command is invalid and error
code “103” is returned.
*With PJ-Net attached and the power OFF, error code “101”
is returned.
*In models not supporting PJ-Net, error code “103” is
returned.
Response
Unacceptable