Sanyo PLC-XM100/L RS232C Expand - Page 63
CR_HMSLOT Command, CR_NMSLOT1 Command, CR_NMSLOT2 Command, CR_NMSLOT3 Command, CR_NMSLOT4 Command
![]() |
View all Sanyo PLC-XM100/L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command "CR_HMSLOT" [CR] Details Get the total number of Input. Acceptable "000_%1" [CR] Response %1 "004 When PJ-Net is attached. "003 When PJ-Net is not attached. Unacceptable "Error Code" [CR] 9.7.11 CR_NMSLOT1 Command Command "CR_NMSLOT1" [CR] Details Get terminal information of Input1 Response Acceptable %1 "000_%1" [CR] "RGB" Unacceptable "Error Code" [CR] 9.7.12 CR_NMSLOT2 Command Command "CR_NMSLOT2" [CR] Details Get terminal information of Input2 Response Acceptable %1 "000_%1" [CR] "5BNC" Unacceptable "Error Code" [CR] 9.7.13 CR_NMSLOT3 Command Command "CR_NMSLOT3" [CR] Details Get terminal information of Input3 Acceptable "000_%1" [CR] Response %1 "VIDEO" Unacceptable "Error Code" [CR] 9.7.14 CR_NMSLOT4 Command Command "CR_NMSLOT4" [CR] Details Get terminal information of Input4 Acceptable "000_%1" [CR] Response "NETWORK" -------- When PJ-Net is attached. *With PJ-Net unattached, this command is invalid and error code "103" is returned. %1 *With PJ-Net attached and the power OFF, error code "101" is returned. *In models not supporting PJ-Net, error code "103" is returned. Unacceptable "Error Code" [CR] 63/79
![](/manual_guide/products/sanyo-plcxm150l-rs232c-expand-5c4ed26/63.png)