MODELS RSL12U AND RSW12U, Check the incoming power., Check the control board., Check the batteries.
View all LiftMaster RSL12U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
MODELS RSL12U AND RSW12U SYMPTOM: Operator does not have power. POWER * (Back of Outlet Housing) Outlet Outlet OUTLET HOUSING DIAGNOSTICS Fuse CONTROL BOARD 3 Check the control board.* Try replacing the fuse on the control board. If that does not work, replace the control board. Black Green White J15 Plug HOT GROUND NEUTRAL Incoming Power Battery 12V 7AH Red Black 1 Check the incoming power.* Check breaker first, then check voltage coming into operator. The voltage should be 120 Vac. 2 Check the batteries.* Check the battery connections. Make sure one 7AH battery OR one 33AH battery is connected. Check the voltage coming from each battery by disconnecting the battery from the operator. A fully charged battery should read 12.8 to 13.3 Vdc per battery. If not, replace the batteries. 26