STEP 6 continued... SOLAR PANEL(S) SOLAR USAGE GUIDE APPENDIX Typical System Standby Battery Current Consumption (mA) System voltage Main board with no radios programmed One or more LiftMaster® remote controls programmed MyQ® device or wireless dual gate programmed Expansion board Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board) Add up current draw by feature and accessory to determine total current draw. 12V 4.2 mA +1.5 mA +3.9 mA +18.5 mA +6.6 mA BATTERY CURRENT DRAW (mA) 7AH battery 10W SOLAR PANEL 6 33 25 27 30 26 50 21 100 20W SOLAR PANEL 6 50 (Two 10W 12V panels in 25 50 parallel) 30 50 100 33 200 30W SOLAR PANEL 6 50 (Three 10W 12V panels in 25 50 parallel) 30 50 100 47 200 19 All numbers are estimates. Actual results may vary. SOLAR GATE CYCLES PER DAY ZONE 1 Two 7AH batteries 36 31 29 24 11 50 50 50 48 20 50 50 50 50 50 33AH battery 7AH battery 38 19 33 15 31 13 26 13 50 37 50 32 50 30 50 12 27 50 46 50 40 50 39 50 20 50 ZONE 2 Two 7AH batteries 22 17 15 11 47 41 40 20 50 50 50 41 14 33AH battery 23 18 17 12 50 47 45 25 7AH battery ZONE 3 Two 7AH batteries 15 19 11 15 13 50 19 29 50 14 24 50 13 23 50 24 33AH battery 22 17 16 35 30 28 10 38