LiftMaster RSL12U RSL12U Installation Manual - Page 36
SYMPTOM, POSSIBLE CAUSES, SOLUTIONS, Edge Sensor does
View all LiftMaster RSL12U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
TROUBLESHOOTING TROUBLESHOOTING CHART continued... SYMPTOM POSSIBLE CAUSES Obstruction in a) Force adjustment needed gate's path does not cause gate to stop and reverse Photoelectric sensor does not stop or reverse gate. a) Incorrect photoelectric sensor wiring b) Defective photoelectric sensor Edge Sensor does a) Incorrect edge sensor wiring not stop or reverse b) Defective edge sensor gate. Alarm sounds for 5 minutes or alarm sounds with a command. Alarm beeps three times with a command. a) Double entrapment occurred (two obstructions within a single activation) a) Low battery SOLUTIONS a) Refer to the Adjustment section to conduct the obstruction test and perform the proper force adjustment that is needed. a) Check photoelectric sensor wiring. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction. b) Replace defective photoelectric sensor. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction. a) Check edge sensor wiring. Retest that activating edge sensor causes moving gate to stop and reverse direction. b) Replace defective edge sensor. Retest that activating edge sensor causes moving gate to stop and reverse direction. a) Check for cause of entrapment (obstruction) detection and correct. Press the reset button to shut off alarm and reset the operator. a) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries On dual-gate system, incorrect gate opens first or closes first. Alarm beeps when running. a) Incorrect Bipart switch setting a) Expansion board setting b) Constant pressure to open or close is given a) Change setting of both operator's Bipart switch settings. One operator should have Bipart switch ON (operator that opens second) and the other operator should have Bipart switch OFF (operator that opens first) a) Pre-warning is set to "ON" b) Constant pressure to open or closed is given Maglock not a) Maglock wired incorrectly working correctly. a) Check that Maglock is wired to N.C. and COM terminals. Check that Maglock has power (do not power maglock from control board accessory power terminals). If shorting lock's NO and COM wires does not activate Maglock, then replace Maglock or Maglock wiring (refer to Wiring Diagrams). 35