LiftMaster RSL12U RSL12U Installation Manual - Page 34

Control Board Leds, Input Leds, Status Leds

Page 34 highlights

CONTROL BOARD LEDS TROUBLESHOOTING STATUS LEDS INPUT OFF POWER ON OFF state AC charger or Solar power available BATT OFF CHARGING ON Not charging Three stage battery charging TIMER OFF The timer is disabled ON The timer is enabled MEDIUM BLINK (1 blink per second) The timer is running FAST BLINK (2 blinks The timer is paused per second) FASTEST BLINK (8 The timer is canceled blinks per second) GATE OFF MOVING ON The gate is stopped The gate is opening or closing MEDIUM BLINK (1 blink per second) Operator is in E1 (single entrapment) FASTEST BLINK (8 The operator is in E2 (double blinks per second) entrapment) BATT LOW OFF No battery error ON Battery low BLINK (1 blink per second) Battery critically low ACC PWR OFF OVLD ON OFF state Accessory overload protector opened SBC INPUT FIRE DEPT INPUT EXIT SHADOW CLOSE EYES/ INTERRUPT CLOSE EDGE OPEN EYES/ EDGE LOCK INPUT LEDS OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Maglock relay inactive ON Maglock relay active STATUS LEDS INPUT LEDS 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

33
TROUBLESHOOTING
STATUS LEDS
INPUT LEDS
CONTROL BOARD LEDS
INPUT LEDS
SBC INPUT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
FIRE DEPT
INPUT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
EXIT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
SHADOW
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
CLOSE EYES/
INTERRUPT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
CLOSE EDGE
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
OPEN EYES/
EDGE
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
LOCK
OFF
Maglock relay inactive
ON
Maglock relay active
STATUS LEDS
INPUT
POWER
OFF
OFF state
ON
AC charger or Solar power
available
BATT
CHARGING
OFF
Not charging
ON
Three stage battery charging
TIMER
OFF
The timer is disabled
ON
The timer is enabled
MEDIUM BLINK (1
blink per second)
The timer is running
FAST BLINK (2 blinks
per second)
The timer is paused
FASTEST BLINK (8
blinks per second)
The timer is canceled
GATE
MOVING
OFF
The gate is stopped
ON
The gate is opening or closing
MEDIUM BLINK (1
blink per second)
Operator is in E1 (single
entrapment)
FASTEST BLINK (8
blinks per second)
The operator is in E2 (double
entrapment)
BATT LOW
OFF
No battery error
ON
Battery low
BLINK (1 blink per
second)
Battery critically low
ACC PWR
OVLD
OFF
OFF state
ON
Accessory overload protector
opened