Viper 320HV Owner Manual - Page 18

Code Hopping, Technology

Page 18 highlights

➜ Table of zones A zone is represented by the number of LED flashes used by the system to identify a particular type of input. Standard input assignments are listed in the following table, along with spaces to write in any optional sensors or switches that you have had installed. ZONE (Number of LED Flashes) DESCRIPTION DEALER-INSTALLED OPTIONS 1 Instant trigger for optional hood or trunk pins 2 A heavier impact detected by the on-board shock sensor 3 Door switch trigger 5 Ignition trigger NOTE: The LED does not report when the warn away response has been activated; it only reports triggered sequences. Code HoppingTM Technology The receiver and transmitter use mathematical formulas called algorithms to change their codes each time the transmitter is used. This Code Hopping™ Technology has been developed to increase the security of the unit. By following this set code sequence, the receiver and transmitter stay synchronized, even if the transmitter is used out of range of the vehicle. If, however, the transmitter is pressed many times out of range, or the battery is removed, the transmitter may get temporar- © 2004 Directed Electronics, Inc. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

15
Table of zones
A zone is represented by the number of LED flashes used by
the system to identify a particular type of input. Standard
input assignments are listed in the following table, along with
spaces to write in any optional sensors or switches that you
have had installed.
ZONE
(Number of
DEALER-INSTALLED
LED Flashes)
DESCRIPTION
OPTIONS
1
Instant trigger for optional
hood or trunk pins
2
A heavier impact detected by
the on-board shock sensor
3
Door switch trigger
5
Ignition trigger
NOTE:
The LED does not report when the warn away response has been
activated; it only reports triggered sequences.
Code Hopping
TM
Technology
The receiver and transmitter use mathematical formulas called
algorithms to change their codes each time the transmitter is
used. This Code Hopping
Technology has been developed to
increase the security of the unit. By following this set code
sequence, the receiver and transmitter stay synchronized,
even if the transmitter is used out of range of the vehicle. If,
however, the transmitter is pressed many times out of range,
or the battery is removed, the transmitter may get temporar-
©
2004 Directed Electronics, Inc.