RIP requirements, HP Scitex ONYX Thrive RIP v12.1 or later: product number D9Z41A

Page 22 highlights

Remote domain hp.com heleni.me Protocol and port https 443 https 443 NOTE: If needed, please instruct the customer IT to create routing rules that route around the proxy for these addresses. ● A minimum upload speed of 5 Mb/s is required. HP provides the following system components: HP provided components ● HP Internal Print Server - PC and power cord - PC LAN card connections: 2 Ethernet ports, one for the e-box LAN cable to connect the printer to the PC, and the other to connect to the network - 2 monitor and power cords - Windows 10 Embedded - HP Internal Print Server software Customer provided components ● Ethernet LAN (minimum 1 Gb/s) connection ● RIP station and software ● CAT-6 LAN cable long enough to connect the printer to the network RIP requirements There are two RIPs offered by HP that may be used with the printer: ● HP Scitex ONYX Thrive RIP v12.1 (or later): product number D9Z41A ● HP Scitex Caldera Grand RIP v11.1 (or later): product number L5E74A The software and hardware requirements of these RIPs are as follows. HP Scitex ONYX Thrive RIP v12.1 or later ● Main Workstation requirements: - Operating System: Microsoft Windows 7 Professional operating system 64-bit or newer (32-bit not supported) NOTE: 32-bit operating systems have a hardware limit of 4 GB of RAM. It is recommended you use 64-bit operating systems for high volume workflows. - Processor: Multi-core processor - RAM: 8 GB minimum (4 GB / core recommended) - Hard Drive: 500 GB (7200 rpm) (250 GB+ free space 18 Chapter 2 Site preparation ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Remote domain
Protocol and port
hp.com
https 443
heleni.me
https 443
NOTE:
If needed, please instruct the customer IT to create routing rules that route around the proxy for
these addresses.
A minimum upload speed of 5 Mb/s is required.
HP provides the following system components:
HP provided components
HP Internal Print Server
PC and power cord
PC LAN card connections: 2 Ethernet ports, one for the e-box LAN cable to connect the printer to the
PC, and the other to connect to the network
2 monitor and power cords
Windows 10 Embedded
HP Internal Print Server software
Customer provided components
Ethernet LAN (minimum 1 Gb/s) connection
RIP station and software
CAT-6 LAN cable long enough to connect the printer to the network
RIP requirements
There are two RIPs offered by HP that may be used with the printer:
HP Scitex ONYX Thrive RIP v12.1 (or later): product number D9Z41A
HP Scitex Caldera Grand RIP v11.1 (or later): product number L5E74A
The software and hardware requirements of these RIPs are as follows.
HP Scitex ONYX Thrive RIP v12.1 or later
Main Workstation requirements:
Operating System: Microsoft Windows 7 Professional operating system 64-bit or newer (32-bit not
supported)
NOTE:
32-bit operating systems have a hardware limit of 4 GB of RAM. It is recommended you use
64-bit operating systems for high volume workflows.
Processor: Multi-core processor
RAM: 8 GB minimum (4 GB / core recommended)
Hard Drive: 500 GB (7200 rpm) (250 GB+ free space