Epson TM-U220 ePOS-Print XML Users Manual - Page 105
<pulse>, Attribute, drawer, Sample program, Supplementary explanation
View all Epson TM-U220 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
Chapter 4 XML Reference This element allows you to send a signal to the drawer kick connector. Attribute drawer If "drawer" and "time" are not specified, the values shown below are set. drawer: drawer_1 time: pulse_100 Attribute value "drawer_1" "drawer_2" time Description Drawer kick connector pin No.2 Drawer kick connector pin No.5 Attribute value "pulse_100" "pulse_200" "pulse_300" "pulse_400" "pulse_500" 100-msec signal 200-msec signal 300-msec signal 400-msec signal 500-msec signal Description Sample program Sends a 100 msec pulse signal to pin No.2 of the drawer kick connector. Supplementary explanation ❏ This does not work in the page mode. ❏ The drawer function cannot be used with the buzzer function. 105
105
Chapter 4
XML Reference
<pulse>
This element allows you to send a signal to the drawer kick connector.
Attribute
drawer
time
Sample program
Sends a 100 msec pulse signal to pin No.2 of the drawer kick connector.
Supplementary explanation
❏
This does not work in the page mode.
❏
The drawer function cannot be used with the buzzer function.
If "drawer" and "time" are not specified, the values shown below are set.
drawer: drawer_1
time: pulse_100
Attribute value
Description
"drawer_1"
Drawer kick connector pin No.2
"drawer_2"
Drawer kick connector pin No.5
Attribute value
Description
"pulse_100"
100-msec signal
"pulse_200"
200-msec signal
"pulse_300"
300-msec signal
"pulse_400"
400-msec signal
"pulse_500"
500-msec signal
<epos-print xmlns="http://www.epson-pos.com/schemas/2011/03/epos-print">
<pulse drawer="drawer_1" time="pulse_100" />