Lamp Status Read Command, CR_LAMPREPL Command, CR_LAMPH Command, CR_LAMPCORRESPH Command,
UPC - 086483074226
View all Sanyo PLC-WXU300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
PLC-WXU300 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL"[CR] Details Get information of Lamp Replacement time Acceptable "000_%1"[CR] "1Y Over lamp replacement time "1N Within lamp replacement time Response %1 "1" means the number of lamps. (1 lamp model→ "1") "Y"/"N" means if it has reached its replacement time or not. e.g. "1Y projector is 1 lamp model and Lamp is over its replacement time Unacceptable "Error code"[CR] 9.9.2 CR_LAMPH Command Command "CR_LAMPH"[CR] Details Get total running time of lamp by hour (h) *Actual running time, not corresponding value Acceptable "000_%1"[CR] Response %1 "00000"~"99999" Unacceptable "Error code"[CR] 9.9.3 CR_LAMPCORRESPH Command Command "CR_LAMPCORRESPH"[CR] Details Get total running time of lamp by hour (h) * Corresponding value, not actual running time Acceptable "000_%1"[CR] Response %1 "00000"~"99999" Unacceptable Error code"[CR] 9.9.4 CR_LAMPMODE Command Command "CR_LAMPMODE"[CR] Details Get setting status of Lamp Mode Acceptable "000_%1"[CR] Response %1 "NORMAL Lamp Mode is Normal "ECO Lamp Mode is Eco Unacceptable "Error code"[CR] 59/72