Sanyo PLC-WXU300 RS232 Expand - Page 43

CF_PJPINCODE Command, 10.27 CF_FANMODE Command, 10.28 CF_FANCONTROL Command

Page 43 highlights

PLC-WXU300 Expand Serial Command Functional Specifications 8.10.26 CF_PJPINCODE Command Command "CF_PJPINCODE_%1"[CR] %1 "0000" - "9999" ---------Set PJ PIN CODE directly Set PJ PIN CODE to release PJ LOCK. PIN CODE cannot be changed by this command. Details -When PJ LOCK is in operation PIN CODE is correct Command is valid (Acceptable) PIN CODE is incorrect Command is invalid(Error Code"102") PIN CODE is out of %1 range Command is invalid (Error Code "? ") -When PJ LOCK is not in operation PIN CODE is within %1 range Command is valid (Acceptable) PIN CODE is out of %1 range Command is invalid (Error Code "? ") Response This command is valid during a dialog "PJ PIN CODE" is displayed after Power On and Count down. Also when PJ LOCK setting is "On1", it is necessary to transmit this command every time lamp turns on. Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8.10.27 CF_FANMODE Command Command "CF_FANMODE_%1"[CR] %1 "L1 Set Fan Mode to L1 "L2 Set Fan Mode to L2 Details Switch Fan Mode When L1 is selected, fan noise after POWER OFF is louder. When L2 is selected, fan noise after POWER OFF becomes quiet. However fan rotates longer than L1. The status set by this command is stored in EEPROM and its setting is effective even after ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.28 CF_FANCONTROL Command Command "CF_FANCONTROL_%1"[CR] "OFF Set Fan control to Off %1 "ON1 Set Fan control to On1 "ON2 Set Fan control to On2 Details Set Fan control setting. The status set by this command is stored in EEPROM and its setting is effective even after ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 42/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-WXU300 Expand Serial Command Functional Specifications
42/72
8.10.26 CF_PJPINCODE Command
Command
“CF_PJPINCODE_%1”[CR]
%1
“0000” – “9999” ---------Set PJ PIN CODE directly
Details
Set PJ PIN CODE to release PJ LOCK.
PIN CODE cannot be changed by this command.
-When PJ LOCK is in operation
PIN CODE is correct ------------------------- Command is valid (Acceptable)
PIN CODE is incorrect ----------------------- Command is invalid(Error Code”102”)
PIN CODE is out of %1 range ------------- Command is invalid (Error Code “? “)
-When PJ LOCK is not in operation
PIN CODE is within %1 range ---------------- Command is valid (Acceptable)
PIN CODE is out of %1 range ---------------- Command is invalid (Error Code “? “)
This command is valid during a dialog “PJ PIN CODE” is displayed after Power On
and Count down.
Also when PJ LOCK setting is “On1”, it is necessary to transmit this command
every time lamp turns on.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.10.27 CF_FANMODE Command
Command
“CF_FANMODE_%1”[CR]
%1
“L1” ---------------------------- Set Fan Mode to L1
“L2” ---------------------------- Set Fan Mode to L2
Details
Switch Fan Mode
When L1 is selected, fan noise after POWER OFF is louder.
When L2 is selected, fan noise after POWER OFF becomes quiet. However fan
rotates longer than L1.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.10.28 CF_FANCONTROL Command
Command
“CF_FANCONTROL_%1”[CR]
%1
“OFF” ---------------------------- Set Fan control to Off
“ON1” ---------------------------- Set Fan control to On1
“ON2” ---------------------------- Set Fan control to On2
Details
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]