Page 50 highlights
PLC-WXU300 Expand Serial Command Functional Specifications 9.4.11 CR_NZRED Command Command "CR_NZRED"[CR] Details Get setting status of Noise Reduction Acceptable "000_%1"[CR] "L1" -------- Noise Reduction for moving image Response %1 "L2" -------- Noise Reduction for still image "OFF" ----- Noise Reduction is OFF Unacceptable "Error code"[CR] 9.4.12 CR_PROGV Command Command "CR_PROGV"[CR] Details Get setting status of Progressive scan Acceptable "000_%a"[CR] "L1 Progressive Mode L1 is selected Response %a "L2 Progressive Mode L2 is selected "FILM Progressive Model FILM is selected "OFF Progressive scan is disabled Unacceptable "Error code"[CR] 9.4.13 CR_IMAGE Command Command "CR_IMAGE"[CR] Details Get image setting status Required data "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4" displayed when selecting IMAGE on OSD menu Acceptable "000_%a"[CR] "DYNAMIC Dynamic "STAND Standard "REAL Real %a "CINEMA Cinema Response "BLACKBOARD Blackboard "COLORBOARD Colorboard "CUSTOM1"~"CUSTOM4 Image1~4 "Error Code"[CR] ---- When the command is invalid due to Unacceptable condition such as Input source "?"[CR When unclear command is received 9.4.14 CR_IMGGMD Command Command "CR_IMGGMD"[CR] Details Get Image Gamma setting status Acceptable "000_%a"[CR] "DYN Dynamic "STD Standard Response %a "REL Real "CNM Cinema "BKB Blackboard Unacceptable "Error code"[CR] 49/72