  • LiftMaster CSW24V | CSW24V Installation Manual - Page 1
    CSW24V™ & CSW24VH™ VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Your model may look different than the model illustrated in this manual. THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.liftmaster.com to locate a professional installing dealer
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 2
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 3
    IMPORTANT NOTE • BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate operator unless you are an Authorized Service Technician. 1 MECHANICAL ELECTRICAL
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 4
    entrapment protection requirements for the UL325 classes. GATE OPERATOR ENTRAPMENT PROTECTION UL325 Classification Swing Gate Operator Primary Type Secondary Type CLASS I-CLASS IV A B1 or B2 In order to complete a proper installation you must satisfy the entrapment protection chart shown
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 5
    of entrapment. Swinging gates shall not open into public access areas. 7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. 11. For a gate operator utilizing a non-contact sensor: a. Reference owner's manual regarding placement
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 6
    II and Class III vehicular horizontal swing gates: 4.1.1 Gates shall be designed, constructed and installed so as not to create an entrapment area between the gate and the supporting structure or other fixed object when the gate moves toward the fully open position, subject to the provisions in
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 7
    monitored photoelectric sensor is not working or loses power or the beam is blocked, then ALL gate operation in that direction will stop. Unmonitored photoelectric sensor models AOMRON and RETROAB are also acceptable. Sensor for Open Cycle Safety Non-Contact Sensor Sensor for Close Cycle ! ! 5
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 8
    edges, and post mounted both inside and outside a horizontal swing gate. Non-contact sensors such as photo eyes MUST be mounted across the gate opening and operate during BOTH the open and close cycles. • Entrapment protection devices MUST be installed to protect anyone who may come near a moving
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 9
    . • SAVE THESE INSTRUCTIONS. • ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. TROUBLESHOOTING To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 10
    DIMENSIONS OPERATOR SPECIFICATIONS This model is intended for use in vehicular swing gate applications: Gate Classifications: CLASS I, II, III, & IV Main AC Supply: 120 Vac or 240 Vac Solar Power Max: 24 Vdc at 50 watts max. Input Rating: • CSW24V: 10 Amps at 120 Vac or 2 Amps at 240 Vac • CSW24VH
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 11
    3-Button station accessory connection • AUX Relays (2) each independently selectable operation: - OPEN LIMIT: ON at open limit switch - CLOSE LIMIT: OFF at close limit switch - GATE MOVING: ON with gate moving - PRE-ALERT DELAY: ON 3 seconds before gate motion - TAMPER: ON when gate manually pulled
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 12
    SITE PREPARATION Check the national and local building codes BEFORE installation. GATE Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (refer to specifications). CONDUIT & CONCRETE PAD Conduit must be UL
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 13
    (Inside Property) The illustration is an example of a compact installation. If the operator arm will hit an obstruction when the gate is in the open position follow the directions for Compact Installation. UPHILL DRIVEWAY INSTALLATION (Side View) (Outside Property) The illustration is an example
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 14
    INSTALLATION ONLY STANDARD INSTALLATION ONLY For compact installation start on page 14. DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR DO NOT run the operator until instructed. Below is a recommended guide for positioning the concrete pad: 1 Measure 1/4 the length of the gate from the gate
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 15
    1/4 of gate length Gate Hinge Center 3 Set Screws Tack weld STANDARD INSTALLATION ONLY 1 Slot Output Shaft Pin ADJUST THE OPERATOR ARM LENGTH to the gate in the open position as shown). Proceed to PAGE 16. TOP VIEW - CLOSED GATE 1 Set Screws E TOP VIEW - OPEN GATE Gate Open 90° Set
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 16
    the handle to avoid damaging the operator. Gate Hinge Center TOP VIEW OF OPERATOR AND GATE Gate Open 90° 26-1/2" Output Shaft Center 9" 28" Handle CONCRETE PAD AND OPERATOR ATTACHMENT Check the national and local building codes before installation. 1 Install the electrical conduit. 2 Pour
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 17
    INSTALLATION COMPACT INSTALLATION ONLY SHORTEN THE OPERATOR ARM For a compact installation the operator arm will have to be shortened. 1 Take the operator arm apart and remove the inner sleeves from the outer tubing. 2 Cut the outer tubing of the operator arm sections to the lengths shown. 3 Put
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 18
    the handle by pushing it down. Test to make sure the operator arm does not slip on the output shaft. INSTALLATION CONTINUED... 3 2 1 2 REMOVE THE PINS FROM THE VENT PLUGS 1 Remove the pin from the vent plug on both the top and bottom gear boxes. Top Gear Box Bottom Gear Box 16 Pin Vent Plug
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 19
    on the OPEN EYES/EDGE terminal. NOTE: Refer to the "Accessory Features on Install the earth ground rod within 3 feet of the operator. 2 Run wire from the earth ground rod to the operator. NOTE: If the operator is not grounded properly the range of the remote controls will be reduced. 17 To Operator
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 20
    solar panel (not provided). Follow the directions according to your application. For dual gate applications, power will have to be connected to each operator WIRING NUMBER OF CYCLES PER DAY Swing Gate Installation (12 ft. 800 lb. gate) Accessories Single Gate 7AH Batteries (standard) 33AH
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 21
    Box Cover POWER WIRING SOLAR PANEL(S) NOT PROVIDED. SEE ACCESSORIES. For solar applications DO NOT use the expansion board and the wireless dual gate feature. These features will substantially decrease the cycle rate and standby time of the operator. The solar panel(s) must be located in an open
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 22
    cable. 2 Connect the wires from the extension cable to the Comm Link terminals on the primary gate operator control board. 3 Route the extension cable to the secondary gate operator's control board. DUAL GATE WIRE TYPE (STRANDED COPPER WIRE) 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 23
    GATES ONLY WIRELESS DUAL GATES Turn on power to the operator. TO ACTIVATE THE WIRELESS FEATURE: 1 Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. 2 Press and release the LEARN RADIO button on the primary operator
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 24
    the LOCK/BIPART DELAY switch to ON for both operators. DUAL GATES ONLY + CONNECT BATTERIES RESET ALARM CONNECT BATTERIES 7AH BATTERIES The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar installation. 1 Turn OFF AC power to the
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 25
    or solar installation. The 33AH application requires the 33AH battery harness (Model K94-36596) and an additional battery tray (Model K1036183) operator. 10 Turn ON the AC power switch on the operator. 11 Plug the J15 plug back into the control board. CONNECT BATTERIES (back of Electrical Box)
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 26
    and release the SET CLOSE or SET OPEN button depending on which limit is being set. 6 Cycle the gate open and close. This automatically sets the force. When limits are set properly the operator will automatically exit limit setting mode. 1 ! CLOSE limit 24 2 PRESS & RELEASE TO BEGIN 3 TO BEGIN
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 27
    adjustments 1 are made, test the operator: 1 Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and close limit positions. 2 Place a solid object between the open gate and a rigid structure. Ensure that the gate, the solid object, and the rigid
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 28
    ). All remote control codes are now erased. NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 29
    cover. The front cover can easily be removed to access the electrical box. To access the reset switch slide the access door up. The front cover and access door can be locked with the key. TO INSTALL THE COVER 1 Remove the operator arm from the output shaft by releasing the handle. 2 Align the
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 30
    , activation of the remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate. HEATER (IF APPLICABLE) The operator may have a heater installed, depending on the model purchased. The heater
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 31
    Attach alert signal (audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close limit Use during servicing only to determine operator cycles Connect emergency access system (Knox box switch, SOS system, etc.) Suggested use if outside temperature remain
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 32
    dial adjusts the force. See Force Adjustment section. The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE). The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section. Open Close Stop Com Fire Dept Com Exit Com Shadow Com Close Eyes Interrupt
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 33
    , N.O. and COM) Normally - open (N.O.) output for solenoid locks Relay activates prior to motor activation and during motor run. Relay is off when motor is off. M Accessory Power Out Switched, (2 terminals) 24 Vdc voltage out to power accessories, will turn off when gate is not in motion to save
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 34
    circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. QUICK CLOSE Switch OFF: No change to the gate's normal operation. ON: When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 35
    FEATURES ON EXPANSION BOARD ACCESSORY FEATURES ON EXPANSION BOARD A Open Input (& common) secured area near gate. Open command - opens a closed gate. Soft open (maintained switch does ENERGIZED Main Board Exit Input Barrier Arm Operator C Auxiliary NO Command RESET ALARM Expansion Board
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 36
    and release the STOP button on the remote control. 7 Press and release the CLOSE button on the remote control again to set the close limit. 8 Cycle the gate open and close. This automatically sets the force. When limits are set properly the operator will automatically exit limit setting mode. LIMIT
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 37
    service the operator. DESCRIPTION Entrapment Protection Devices Warning Signs Manual Disconnect Sprockets and Chains Gate Accessories Electrical Chassis Mounting Bolts Operator Batteries TASK Check and test for proper operation only LiftMaster part 29-NP712 for replacement batteries. The operator
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 38
    . The control board LEDs indicate the status of the operator, assist with programming, and diagnose potential problems with the operator. LIMIT SETUP LEDS GREEN XMITTER LED DIAGNOSTIC CODES LEDS STATUS LEDS INPUT LEDS RESET ALARM SET OPEN LED BLINKING OFF BLINKING BLINKING ON ON LIMIT SETUP
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 39
    STATUS LEDS INPUT POWER OFF OFF state ON AC charger or Solar power available BATT OFF CHARGING ON Not charging Trickle charge FAST BLINK BLINK The timer is cancelled GATE MOVING OFF The gate is stopped ON The gate is opening or closing FASTEST BLINK The operator is in E2 BATT LOW
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 40
    TROUBLESHOOTING TROUBLESHOOTING CHART FAULT Operator does not run and diagnostic LED not on. Control board powers up, but motor does not run. Relay clicks with command, but motor does not turn on. Arm moves, but cannot set correct limits. Gate does not fully open by AC or solar power or replace
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 41
    TROUBLESHOOTING TROUBLESHOOTING CHART FAULT Gate stops during travel and reverses immediately. Gate opens, but will not close. Gate closes, but will not open. Gate does not close from Timer-to-Close. Vehicle Exit loop activation does not cause gate to open. CLOSE EYES/ Interrupt loop does not
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 42
    -gate system, incorrect gate opens first or closes first. Expansion board function not controlling gate. Maglock not working correctly. a) Double entrapment occurred a) Low battery with loss of AC/solar power a) Defective or incorrect Operator-to-Operator wiring b) Incorrect Operator-to-Operator
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 43
    board TROUBLESHOOTING CHART CORRECTIONS a) Disconnect all accessory powered devices and measure accessory power voltage accessories one at a time, measuring accessory voltage after every new connection. b) Replace defective control board a) Check that Quick Close setting is ON b) Check operation
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 44
    and battery BEFORE installing or servicing operator. Field Wiring Edge G DIAGRAM 229C Coaxial Antenna Cable Antenna CONTROL BOARD LOCK (not provided) Solenoid Lock (Optional) N.O. COM N.C. LOCK Maglock (Optional) (not provided) Two 12V Solar Panels in Series -+ - + Accessory Power Outlets
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 45
    For post-mounting model CSW24V commercial swing operator (also CSW200 commercial swing operator). Posts not included. Model MPEL REMOTE ANTENNA EXTENSION KIT The remote antenna extension kit allows the antenna to be remotely installed. Model 86LM MISCELLANEOUS HEATER Keeps operator, gearbox and
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 46
    pin Gear Box (top) Battery Tray Battery, 7AH, 12 Vdc Toroid Transformer APE Assembly with plastic tray, RPM board with mounting hardware Bridge Rectifier Main Board with heat sink Expansion Board EMI Board with 120V receptacles and AC power switch Antenna Motor, 1/2 HP, 24 Vdc Electrical Box with
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 47
    REPAIR PARTS 1 12 7 5 28 9 6 19 26 27 8 29 10 22 11 20 3 4 18 13 14 21 15 23 24 45 17 16 25 2
  • LiftMaster CSW24V | CSW24V Installation Manual - Page 48
    the CSW24V™ and CSW24VH™ are free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase]. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

CSW24V™ & CSW24VH™
VEHICULAR SWING GATE OPERATOR
INSTALLATION MANUAL
Your model may look different than the model illustrated in this manual.
UL991
compliant
UL325
compliant
THIS PRODUCT IS TO BE
INSTALLED AND SERVICED BY A
TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
Visit www.liftmaster.com to
locate a professional installing
dealer in your area.
This model is for use on
vehicular passage gates ONLY
and not intended for use on
pedestrian passage gates.
This model is intended for use in
Class I, II, III and IV vehicular
swing gate applications.