8.21.2.2 Data transfer Once an SCT command has been issued, status can be checked and data can be transferred. Data transfer uses log page E1h. 8.21.2.2.1 Read/Write SCT Data Using SMART Command Block Output Registers Register 76543210 Feature D5h(Read)/D6h(Write) Sector Count Number of sectors to be transferred Sector Number E1h Cylinder Low 4Fh Cylinder High C2h Device/Head - - -D- - - - Command B0h Table 63 Input Registers of SCT Data Transfer Using SMART 8.21.2.2.2 Read/Write SCT Data Using Read/Write Log Ext Command Block Output Registers Register 76543210 Feature Current Reserved Previous Reserved Sector Count Current 01h Previous 00h LBA Low Current E1h Previous Reserved LBA Mid Current 00h Previous 00h LBA High Current Reserved Previous Reserved Device/Head - - -D- - - - Command 2Fh(Read)/3Fh(Write) Table 64 Input Registers of SCT Data Transfer using Read/Write Log Ext HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 97