INTERFACE SPECIFICATIONS, Parallel Interface, Signal Timing, See Table 1-12.
![]() |
View all Epson H5200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
General Description EPL+OOO/5200/Action Laser 1000/1500 Service Manual 1.3 INTERFACE SPECIFICATIONS TIW EPL-5000/5200 and ActionLaser 1500 are equipped with the following external interfaces: H Centronics@ parallel interface u RS-232C interface s Optional Type B interface (except for C82305*/C82306*) The ActionLaser 1000 is equipped with the following external interfaces: u Centronics@ parallel interface 9 Optional Type B host interface (including C82305*/C82306*) 1.3.1 Parallel Interface Type: System: Handshaking: CentronicsC> STROBE synchronization, 8-bit parallel data transfer BUSY and ACKNOWLEDGE signals Note: While the SelecType setting for BUSY delay is "MlN," the handshaking signal is BUSY only. Comector type: P90-25027-1 (Amphenol) receptacle Applicable plug: 57-30360 (Amphenol or equivalent) Transfer speed: About 75,000 bytes/second (max.) (EPL-5000/ActionLaser 1000) About 125,000 bytes/second (max.) (EPL-5200/ActionLaser 1500) Siamal timing: See Figure 1-3. Signal description: See Table 1-12. (1) (2) ( 'r DATA 1-8 ) : VALID VALID , :3) , STOROBE / (4) - . (7) < > BUSY / \ ACKNLG f +--+ (6) Figure 1-3. Signal Timing Table 1-12. Signal Timing No. Description (1) Data set up (2) DATA hold (3) STROBE (pulse width) (4) BUSY delay ACKNLG to BUSY -5 o (5) +5 No ACKNLG pulse (6) ACKNLG pulse width (7) ACKNLG to STROBE Time (p.sec.) 0.5 (min.) 0.5 (min.) 0.5 (min.) 4.0 (max.) o (typ.) 5 (typ.) 10 (typ.) - 10 (typ.) O (min.) 1-14 Rev. A