Epson ColorWorks C7500 ESC/label Command List TM-C7500 Series - Page 30

Rev.d, Sheet26

Page 30 highlights

Command List of the Alphabetical Order 1"Priority" indicates the function is executed with priority. Command Function identifier Command name Description Classification Command code Description of parameters Definition range for ESC/Label ^S(C MT Set auto cleaning on designated time Sets auto cleaning on Printer setting designated time (enable/disable auto cleaning on designated time or time to start auto cleaning). ^S(CMT,b,c ^S(C MV Set nozzle self-test operation Sets nozzle self-test operations (permitted clogged nozzle number, selftest interval in printing (number of labels), operation at clogged nozzle detection, or enable/disable nozzle selftest). Printer setting ^S(CMV,b,c ^S(C PC Set image correction Sets correction for image to Printer setting be printed (banding reduction , color correction mode, ink profile and brightness adjustment, enable/disable feather edge function, or ratio of black to composite). ^S(CPC,b,c ^S(C ^S(C Set LED notification This command sets whether Control panel ^S(CSL,b,c SL setting at ink cartridge low to use the LED to notify the user that ink cartridge low is occurred. Set buzzer Sets the buzzer settings for Printer setting ^S(CUB,b,c printing operations or the volume level. UB b=S: Enable/disable auto cleaning on designated time c = E/D E: Enabled D: Disabled b=T: Time to start auto cleaning c = hh:mm hh & mm are number within two digits hh = 00 to 23 mm = 00 to 59 b=C: Permitted clogged nozzle number 0 ≤ c ≤ 9999 b=I: Self-test interval in printing 0 ≤ c ≤ 99999999 (number of labels) 0: Job separator only b=O: Operation at clogged nozzle detection b=S: Enable/disable nozzle self-test b=B: Banding reduction b=C: Color correction mode c = C/N C: Continue printing N: Notify c = E/D E: Enabled D: Disabled -9999 ≤ c ≤ 9999 c = ASCII, 1 character b=D: Ink profile and brightness adjustment b=E: Enable/disable feather edge function b=P: Ratio of black to composite b=N: LED notification setting at Inkcartridge low b=S: Buzzer timing b=Z: Buzzer volume -9999 ≤ c ≤ 9999 c = E/D E: Enabled D: Disabled -9999 ≤ c ≤ 9999 c = E/D E: Enabled D: Disabled c = N/E/L N: None E: Each label L: Last label c = N/S/M/L/X N: OFF S: Soft M: Medium L: Loud X: Max TM-C7500 series Definition range c = E/D E: Enabled D: Disabled c = hh:mm hh & mm are number within two digits hh = 00 to 23 mm = 00 to 59 0 ≤ c ≤ 10 0 ≤ c ≤ 500 0: Job separator only Factory-set Corresponding ZPL II command Priority 1 initial value D 00:00 Low 6 0 Low c = C/N C C: Continue printing N: Notify c = E/D E E: Enabled D: Disabled -2 ≤ c ≤ 2 0 c = N/E N N: preferred color E: EPSON standard -6 ≤ c ≤ 4 0 Low c = E/D D E: Enabled D: Disabled -6 ≤ c ≤ 4 0 c = E/D E E: Enabled D: Disabled Low c = N/L N: None L: Last label None c = N/S/M/L/X M Low N: OFF S: Soft M: Medium L: Loud X: Max ESC/Label Command List Rev.D SHEET26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

Command List of the Alphabetical Order
1
"Priority" indicates the function is executed with priority.
Definition range
Factory-set
initial value
TM-C7500 series
Corresponding ZPL II
command
Priority
1
Command
Function
identifier
Command name
Description
Classification
Command code
Description of parameters
Definition range for ESC/Label
b=S: Enable/disable auto cleaning on
designated time
c = E/D
E: Enabled
D: Disabled
c = E/D
E: Enabled
D: Disabled
D
b=T: Time to start auto cleaning
c = hh:mm
hh & mm are number within two digits
hh = 00 to 23
mm = 00 to 59
c = hh:mm
hh & mm are number within two digits
hh = 00 to 23
mm = 00 to 59
00:00
b=C: Permitted clogged nozzle number
0 ≤ c ≤ 9999
0 ≤ c ≤ 10
6
b=I: Self-test interval in printing
(number of labels)
0 ≤ c ≤ 99999999
0: Job separator only
0 ≤ c ≤ 500
0: Job separator only
0
b=O: Operation at clogged nozzle
detection
c = C/N
C: Continue printing
N: Notify
c = C/N
C: Continue printing
N: Notify
C
b=S: Enable/disable nozzle self-test
c = E/D
E: Enabled
D: Disabled
c = E/D
E: Enabled
D: Disabled
E
b=B: Banding reduction
-9999 ≤ c ≤ 9999
-2 ≤ c ≤ 2
0
b=C: Color correction mode
c = ASCII, 1 character
c = N/E
N: preferred color
E: EPSON standard
N
b=D: Ink profile and brightness
adjustment
-9999 ≤ c ≤ 9999
-6 ≤ c ≤ 4
0
b=E: Enable/disable feather edge
function
c = E/D
E: Enabled
D: Disabled
c = E/D
E: Enabled
D: Disabled
D
b=P: Ratio of black to composite
-9999 ≤ c ≤ 9999
-6 ≤ c ≤ 4
0
^S(C
SL
Set LED notification
setting at ink
cartridge low
This command sets whether
to use the LED to notify the
user that ink cartridge low is
occurred.
Control panel
^S(CSL,b,c
b=N: LED notification setting at
Inkcartridge low
c = E/D
E: Enabled
D: Disabled
c = E/D
E: Enabled
D: Disabled
E
Low
b=S: Buzzer timing
c = N/E/L
N: None
E: Each label
L: Last label
c = N/L
N: None
L: Last label
None
b=Z: Buzzer volume
c = N/S/M/L/X
N: OFF
S: Soft
M: Medium
L: Loud
X: Max
c = N/S/M/L/X
N: OFF
S: Soft
M: Medium
L: Loud
X: Max
M
Low
Low
Low
^S(CMV,b,c
^S(CPC,b,c
^S(CUB,b,c
Low
^S(CMT,b,c
^S(C
MV
^S(C
PC
^S(C
UB
^S(C
MT
Set buzzer
Sets the buzzer settings for
printing operations or the
volume level.
Printer setting
Printer setting
Printer setting
Printer setting
Set image correction
Sets correction for image to
be printed (banding reduction
, color correction mode, ink
profile and brightness
adjustment, enable/disable
feather edge function, or ratio
of black to composite).
Set nozzle self-test
operation
Sets nozzle self-test
operations (permitted
clogged nozzle number, self-
test interval in printing
(number of labels), operation
at clogged nozzle detection,
or enable/disable nozzle self-
test).
Set auto cleaning on
designated time
Sets auto cleaning on
designated time
(enable/disable auto cleaning
on designated time or time to
start auto cleaning).