Epson ColorWorks C7500 ESC/label Command List TM-C7500 Series - Page 12

Rev.d, Sheet8

Page 12 highlights

Command List of the Alphabetical Order 1"Priority" indicates the function is executed with priority. Command ^BX ^BY Function identifier Command name Description Classification Command code Description of parameters Definition range for ESC/Label TM-C7500 series Definition range Factory-set Corresponding ZPL II command Priority 1 initial value Data Matrix Sets the Data Matrix symbol Barcode to the field. ^BXo,s,e,c,r,d,i,f o: Data Matrix field orientation s: Data Matrix module size [dot] e: Data Matrix error correction level c: Data Matrix column count o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) 1 ≤ s ≤ 32000 e = 0/50/80/100/140/200 0: ECC000 50: ECC050 80: ECC080 100: ECC100 140: ECC140 200: ECC200 9 ≤ c ≤ 49 If e = 200, then 10 ≤ c ≤ 144 o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) 1 ≤ s ≤ 14173 e = 200 200: ECC200 square (f = 1): c = 10/12/14/16/18/20 /22/24/26/32/36/40 /44/48/52/64/72/80/88 /96/104/120/132/144 rectangular (f = 2): r = 8: c = 18/32 r = 12: c = 26/36 r = 16: c = 36/48 r: Data Matrix line count d: Data Matrix data type 9 ≤ r ≤ 49 If e = 200, then 10 ≤ r ≤ 144 d = 1/2/3/4/5/6 1: Numerals and blank characters 2: Capital letters of the alphabet (A to Z) and blank characters 3: Numerals, capital letters of the alphabet (A to Z), blank characters, periods , commas , dashes , and slashes . 4: Numerals, capital letters of the alphabet (A to Z), and blank characters 5: ASCII code (00H to 7EH) 6: ASCII code (00H to FFH) square (f = 1): r = 10/12/14/16/18/20 /22/24/26/32/36/40/ 44/48/52/64/72/80/88 /96/104/120/132/144 rectangular (f = 2): r = 8/12/16 d = 1/2/3/4/5/6 1: Numerals and blank characters 2: Capital letters of the alphabet (A to Z) and blank characters 3: Numerals, capital letters of the alphabet (A to Z), blank characters, periods , commas , dashes , and slashes . 4: Numerals, capital letters of the alphabet (A to Z), and blank characters 5: ASCII code (00H to 7EH) 6: ASCII code (00H to FFH) ^BX Low Set barcode parameters default values Sets the default values for Barcode parameters used in barcodes. ^BYx,n,h i: Data Matrix ECC200 escape sequence Any ASCII single character identifier f:Data Matrix ECC200 symbol shape f = 1/2 1: Square 2: Rectangle x: Module width [dot] n: Bar width ratio h: Barcode height [dot] 1 ≤ x ≤ 9999 2.0 ≤ n ≤ 3.0 1 ≤ h ≤ 32000 Any ASCII single character f = 1/2 1: Square 2: Rectangle 1 ≤ x ≤ 85 2.0 ≤ n ≤ 3.0 1 ≤ h ≤ 14173 ^BY Low ESC/Label Command List Rev.D SHEET8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

Command List of the Alphabetical Order
1
"Priority" indicates the function is executed with priority.
Definition range
Factory-set
initial value
TM-C7500 series
Corresponding ZPL II
command
Priority
1
Command
Function
identifier
Command name
Description
Classification
Command code
Description of parameters
Definition range for ESC/Label
o: Data Matrix field orientation
o = N/R/I/B
N: Normal
R: 90° rotation (clockwise)
I: 180° rotation
B: 270° rotation (clockwise)
o = N/R/I/B
N: Normal
R: 90° rotation (clockwise)
I: 180° rotation
B: 270° rotation (clockwise)
s: Data Matrix module size [dot]
1 ≤ s ≤ 32000
1 ≤ s ≤ 14173
e: Data Matrix error correction level
e = 0/50/80/100/140/200
0: ECC000
50: ECC050
80: ECC080
100: ECC100
140: ECC140
200: ECC200
e = 200
200: ECC200
c: Data Matrix column count
9 ≤ c ≤ 49
If e = 200, then 10 ≤ c ≤ 144
square (f = 1):
c = 10/12/14/16/18/20
/22/24/26/32/36/40
/44/48/52/64/72/80/88
/96/104/120/132/144
rectangular (f = 2):
r = 8: c = 18/32
r = 12: c = 26/36
r = 16: c = 36/48
r: Data Matrix line count
9 ≤ r ≤ 49
If e = 200, then 10 ≤ r ≤ 144
square (f = 1):
r = 10/12/14/16/18/20
/22/24/26/32/36/40/
44/48/52/64/72/80/88
/96/104/120/132/144
rectangular (f = 2):
r = 8/12/16
d: Data Matrix data type
d = 1/2/3/4/5/6
1: Numerals and blank characters
2: Capital letters of the alphabet (A to Z)
and blank characters
3: Numerals, capital letters of the alphabet
(A to Z), blank characters, periods <.>,
commas <,>, dashes <->, and slashes </>.
4: Numerals, capital letters of the alphabet
(A to Z), and blank characters
5: ASCII code (00H to 7EH)
6: ASCII code (00H to FFH)
d = 1/2/3/4/5/6
1: Numerals and blank characters
2: Capital letters of the alphabet (A to Z)
and blank characters
3: Numerals, capital letters of the alphabet
(A to Z), blank characters, periods <.>,
commas <,>, dashes <->, and slashes </>.
4: Numerals, capital letters of the alphabet
(A to Z), and blank characters
5: ASCII code (00H to 7EH)
6: ASCII code (00H to FFH)
i: Data Matrix ECC200 escape sequence
identifier
Any ASCII single character
Any ASCII single character
f:Data Matrix ECC200 symbol shape
f = 1/2
1: Square
2: Rectangle
f = 1/2
1: Square
2: Rectangle
x: Module width [dot]
1 ≤ x ≤ 9999
1 ≤ x ≤ 85
n: Bar width ratio
2.0 ≤ n ≤ 3.0
2.0 ≤ n ≤ 3.0
h: Barcode height [dot]
1 ≤ h ≤ 32000
1 ≤ h ≤ 14173
^BX
Low
^BY
Set barcode
parameters default
values
Sets the default values for
parameters used in barcodes.
Barcode
^BYx,n,h
^BY
Low
^BX
Data Matrix
Sets the Data Matrix symbol
to the field.
Barcode
^BXo,s,e,c,r,d,i,f
ESC/Label Command List
Rev.D
SHEET8