Adaptec 1430SA User Guide - Page 65

VERSION, Command Switches, AFU Command Line - Step-by-Step

Page 65 highlights

Appendix C: Using the AFU for DOS ● 65 Example The following example shows a typical system response after a VERIFY command has been performed: A:\> AFU VERIFY /C 0 Adaptec Flash Utility V1.0-0 B1406 (c)Adaptec Inc. 1999-2005. All Rights Reserved. Reading flash image file (Build 1406) Controller #0: Adaptec AAR-1430 File: Checksum: 642C [VALID] (Build 1406) File: Checksum: 642C [VALID] (Build 1406) Verified Successfully VERSION The VERSION command displays version information about the flash components on a HostRAID controller. Command Syntax The command syntax for the VERSION command is as follows: AFU VERSION [/C] Command Switches For details on the /C switch, see SAVE on page 63. Example The following example displays version information about all supported HostRAID controllers: A:\> AFU VERSION /C 0 Adaptec Flash Utility V1.0-0 B1406 (c)Adaptec Inc. 1999-2005. All Rights Reserved. Version Information for Controller #0 (Adaptec AAR-1430) ROM: Build 1406 [VALID] AFU Command Line - Step-by-Step This section provides step-by step instructions for updating the flash. To update the flash using the AFU command line: 1 Shut down the computer. 2 Insert the bootable disk that contains the AFU utility. 3 Turn on the computer. 4 Enter the system setup utility and verify that your computer is set up to boot from the bootable disk.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

Appendix C: Using the AFU for DOS
65
Example
The following example shows a typical system response after a
VERIFY
command has been
performed:
A:\> AFU VERIFY /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Reading flash image file (Build 1406)
Controller #0: Adaptec AAR-1430
File: Checksum: 642C [VALID] (Build 1406)
File: Checksum: 642C [VALID] (Build 1406)
Verified Successfully
VERSION
The
VERSION
command displays version information about the flash components on a
HostRAID controller.
Command Syntax
The command syntax for the
VERSION
command is as follows:
AFU VERSION [/C<
Controller ID
>]
Command Switches
For details on the /C switch, see
SAVE
on page 63
.
Example
The following example displays version information about all supported HostRAID
controllers:
A:\> AFU VERSION /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Version Information for Controller #0 (Adaptec AAR-1430)
ROM: Build 1406 [VALID]
AFU Command Line – Step-by-Step
This section provides step-by step instructions for updating the flash.
To update the flash using the AFU command line:
1
Shut down the computer.
2
Insert the bootable disk that contains the AFU utility.
3
Turn on the computer.
4
Enter the system setup utility and verify that your computer is set up to boot from the
bootable disk.