2014 Polaris 800 Pro RMK Owners Manual - Page 117

2014 Polaris 800 Pro RMK Manual

Page 117 highlights

MAINTENANCE Battery Battery Charging For a refresh charge, follow all instructions carefully. 1. Check the battery voltage with a voltmeter or multimeter. A fully charged battery will register 12.8 V or higher. 2. If the voltage is less than 12.8 volts, recharge the battery at 1.2 amps or less until the battery voltage is 12.8 or greater. Tip: When using an automatic charger, refer to the charger manufacturer's instructions for recharging. When using a constant current charger, use the following guidelines for recharging. WARNING! An overheated battery may explode, causing severe injury or death. Always watch charging times carefully. Stop charging if the battery becomes very warm to the touch. Allow it to cool before resuming charging. Tip: Always verify battery condition before and 1-2 hours after the end of charging. State of Charge 100% Charge Time Voltage 12.8-13.0 volts Action None, check at 3 mos. from date of manufacture May need slight charge, if no charge given, check in 3 months Needs charge Needs charge Needs charge with desulfating charger (Using constant current charger @ standard amps specified on top of battery) None required 75%-100% 12.5-12.8 volts 3-6 hours 50%-75% 25%-50% 0%-25% 12.0-12.5 volts 11.5-12.0 volts 11.5 volts or less 5-11 hours At least 13 hours, verify state of charge At least 20 hours 115

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

115
MAINTENANCE
Battery
Battery Charging
For a refresh charge, follow all instructions carefully.
1.
Check the battery voltage with a voltmeter or multimeter. A fully
charged battery will register 12.8 V or higher.
2.
If the voltage is less than 12.8 volts, recharge the battery at 1.2 amps
or less until the battery voltage is 12.8 or greater.
Tip:
When using an automatic charger, refer to the charger manufacturer's
instructions for recharging. When using a constant current charger, use the
following guidelines for recharging.
WARNING!
An overheated battery may explode, causing severe injury or
death. Always watch charging times carefully. Stop charging if the battery
becomes very warm to the touch. Allow it to cool before resuming charging.
Tip:
Always verify battery condition before and 1-2 hours after the end of
charging.
State of
Charge
Voltage
Action
Charge Time
(Using constant current
charger @ standard amps
specified on top of battery)
100%
12.8-13.0 volts
None, check at 3
mos. from date of
manufacture
None required
75%-100%
12.5-12.8 volts
May need slight
charge, if no
charge given,
check in 3 months
3-6 hours
50%-75%
12.0-12.5 volts
Needs charge
5-11 hours
25%-50%
11.5-12.0 volts
Needs charge
At least 13 hours,
verify state of charge
0%-25%
11.5 volts or less
Needs charge with
desulfating charger
At least 20 hours