Switch setting and function, Initial, setting, Remarks, Make/Break ratio in DP

Page 27 highlights

SW DATA NO. NO. ITEM 1 Reserved 2 Reserved EOL detection timer SW 12 3 4 5 Reserved 6 Reserved 7 Reserved 8 Reserved DTMF ON time 1 2 3 SW DTMF OFF time 13 4 5 6 7 Make/Break ratio in DP 8 Reserved Inter digit pause time SW 1 14 2 3 4 Change to PB from DP by " 5 Reserved 6 Reserved 7 Reserved 8 Reserved 1 Reserved 2 Reserved 3 Reserved SW 4 Reserved 15 5 Reserved 6 Reserved 7 Reserved 8 Reserved 1 Reserved 2 Reserved 3 Reserved SW 4 Reserved 16 5 Reserved 6 Reserved 7 Reserved 8 Reserved Switch setting and function 1 0 No. 3 No. 4 13sec 0 0 25sec 0 1 5sec 1 0 5sec 1 0 70ms 90ms 95ms 100ms 110ms 120ms 140ms 150ms 100ms 110ms 120ms 135ms 140ms 150ms 180ms 200ms 40/60 " Key 800ms 840ms 880ms 900ms 1000ms Not used Not used Not used Yes No. 1 0 0 0 0 1 1 1 1 No. 4 0 0 0 0 1 1 1 1 No. 2 0 0 1 1 0 0 1 1 No. 5 0 0 1 1 0 0 1 1 33/67 No. 1 0 0 0 0 1 1 1 1 No. 2 0 0 1 1 0 0 1 1 No No. 3 0 1 0 1 0 1 0 1 No. 6 0 1 0 1 0 1 0 1 No. 3 0 1 0 1 0 1 0 1 FO-IS125N Initial setting 0 0 0 0 0 0 0 0 0 Remarks 0 1 1 0 1 0 1 0 0 0 0 1 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 2 - 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

FO-IS125N
2 – 14
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
1
0
SW
12
1
Reserved
0
2
Reserved
0
3
4
EOL detection timer
13sec
25sec
5sec
5sec
0
No. 3
0
0
1
1
0
No. 4
0
1
0
0
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW
13
1
2
3
DTMF ON time
No. 1
No. 2
No. 3
0
1
1
70ms
0
0
0
90ms
0
0
1
95ms
0
1
0
100ms
0
1
1
110ms
1
0
0
120ms
1
0
1
140ms
1
1
0
150ms
1
1
1
4
5
6
DTMF OFF time
No. 4
No. 5
No. 6
0
1
0
100ms
0
0
0
110ms
0
0
1
120ms
0
1
0
135ms
0
1
1
140ms
1
0
0
150ms
1
0
1
180ms
1
1
0
200ms
1
1
1
7
Make/Break ratio in DP
40/60
33/67
1
8
Reserved
0
SW
14
1
2
3
Inter digit pause time
No. 1
No. 2
No. 3
0
0
0
800ms
0
0
0
840ms
0
0
1
880ms
0
1
0
900ms
0
1
1
1000ms
1
0
0
Not used
1
0
1
Not used
1
1
0
Not used
1
1
1
4
Change to PB from DP by "
" Key
Yes
No
1
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW
15
1
Reserved
0
2
Reserved
1
3
Reserved
1
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW
16
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0