Panasonic WU-216MF2U9 - Technical Data Manual - Page 23
Example 1, Example 2
View all Panasonic WU-216MF2U9 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
11.. MMooddeell SSeelleeccttiinogn aanndd CCaappaacciittyy CCaallccuullaattoorr Design of 3WAY VRF SYSTEM Design of 3WAY VRF SYSTEM Example 1 Outdoor unit 1 L4: 99ft. (30m) Portion increased by one size is overlapped but only one size is increased. LF: 49ft. (15m) LH: 115ft. (35m) LG: 180ft. (40m) Type 48 L2': 238ft. (72m) Type 48 L2: 263ft. (80m) Type 09 Type 18 Type 18 1. Check the portion for one size increase. ΔL Total capacity of indoor units Length for sizing up L2 system L2' system 164ft. (50m) 139ft. (42m) 47,800 BTU/h (14kW) 95,600 BTU/h (28kW) 39ft. (12m) 66ft. (20m) 1 L2 combined indoor units Increase the discharge, suction and liquid tubes 39ft. (12m) by one size from the 1st distribution joint to be directed towards L2 indoor units. LF: Increase 39ft. (12m) by one size among 49ft. (15m). LG: No increase by one size L2' combined indoor units 2 Increase the discharge, suction and liquid tubes 66ft. (20m) by one size from the 1st distribution joint to be directed towards L2' indoor units. LF: Increase all 49ft. (15m) by one size LH: Increase 16ft. (5m) by one size among 115ft. (35m). 2. Final result Before sizing up After sizing up Tube length Size up length 3 LF ø1-1/8" / ø7/8" / ø1/2" ø1-3/8" / ø1-1/8" / ø5/8" 49ft. (15m) 49ft. (15m) LG ø3/4" / ø5/8" / ø3/8" No size up 131ft. (40m) 0 ft. (0m) LH ø7/8" / ø3/4" / ø3/8" ø1-1/8" / ø7/8" / ø1/2" 115ft. (35m) 16ft. (5m) * The LH is only 16ft. (5m) from the 2nd distribution joint. * The size increased portion is overlapped at the LF but it has only one size increase. 4 Example 2 Outdoor unit 1 Outdoor unit 2 L2: 197ft. (60m) LF: 66ft. (20m) LG: 33ft. (10m) 5 L4: 33ft. (10m) Type 15 Type 48 Type 48 1. Checking the portion for one size increase Δ L Total capacity of indoor units Length for sizing up 6 L2 system 164ft. (50m) 110,600 BTU/h (32.4kW) 66ft. (20m) L2 combined indoor units Increase the discharge, suction and liquid tubes 92ft. (28m) by one size from the 1st distribution joint to be directed towards L2 indoor units. LF: Increase 66ft. (20m) by one size. 7 LG: Increase 26ft. (8m) by one size among 33ft. (10m). 2. Final result Before sizing up After sizing up Tube length Size up length LF ø1-1/8" / ø3/4" / ø1/2" LG ø7/8" / ø3/4" / ø3/8" ø1-3/8" / ø7/8" / ø5/8" ø1-3/8" / ø7/8" / ø1/2" 66ft. (20m) 33ft. (10m) 66ft. (20m) 26ft. (8m) 8 * The LG is only 26ft. (8m) from the 2nd distribution joint.LG * It is possible to increase the LG to 33ft. (10m) by one size. 2 - 7 9