Panasonic WU-216MF2U9 - Technical Data Manual - Page 103
Unit Specifications 4, R410A / [18.3
View all Panasonic WU-216MF2U9 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
1. Outdoor Unit 3WAY VRF SYSTEM Unit Specifications Unit Specifications (4) Combination Model Name WU-216MF2U9 WU-240MF2U9 Outdoor unit Single Model Name U-72MF2U9 U-72MF2U9 U-72MF2U9 U-72MF2U9 U-72MF2U9 U-96MF2U9 Performance test condition AHRI Standard 1230 AHRI Standard 1230 Nominal Cooling capacity Heating capacity Btu/h (kW) Btu/h (kW) 216,000 (63.3) 243,000 (71.2) 240,000 (70.3) 270,000 (79.1) Indoor unit Ducted (Type F2) Ducted (Type F2) Capacity Btu/h 216,000 240,000 Cooling EER 11.1 10.3 Rating Standard AHRI 1230 High Heating 47F IEER SCHE Capacity COP Btu/h 19.2 23.6 232,000 3.40 19.1 24.2 258,000 3.30 Low Heating Capacity Btu/h 162,000 184,000 17F COP 2.54 2.51 Power supply Ø, V/Hz Voltage V Electrical Ratings Ducted cooling Amperes Power input Power factor A kW % 3Ø 208/230V 60Hz 208 / 230 52.9 / 48.3 17.9 / 17.9 94 / 93 3Ø 208/230V 60Hz 208 / 230 63.5 / 58.0 1 21.5 / 21.5 94 / 93 Outdoor Unit only Ducted heating Amperes Power input Power factor A kW % 54.3 / 49.7 18.6 / 18.6 95 / 94 61.9 / 56.6 21.2 / 21.2 95 / 94 Starting amperes A Min Circuit Ampacity A Max Overcurrent Protection A 1 / 1 - 1 / 1 - 2 Design Pressure High side psi Low side psi - - Operation sound dB(A) 58.0 (Quiet mode : 55.0) 59.0 (Quiet mode : 56.0) Type/Quantity Inverter driven Rotary / 1 + 1 + 1 Inverter driven Rotary / 1 + 1 + 1 Compressor Refrigeration oil Type Charge amount gal(liters) FV68S (Ether oil) [1.03 (3.9)] + [1.03 (3.9)] + [1.03 (3.9)] FV68S (Ether oil) [1.03 (3.9)] + [1.03 (3.9)] + [1.03 (3.9)] Crankcase heater W Capacity control range % [30] + [30] + [30] (at 230 V) 7 - 100 [30] + [30] + [30] (at 230 V) 7 - 100 3 Type/Quantity Propeller / 1 + 1 + 1 Propeller / 1 + 1 + 1 Fan Air flow External static pressure CFM Pa (in. WC) [7,000] + [7,000] + [7,000] 0 ~ 80 (0 ~ 0.32) [7,000] + [7,000] + [8,100] 0 ~ 80 (0 ~ 0.32) Fan motor output W / Pole number [750] + [750] + [750] / 8 [750] + [750] + [750] / 8 Refrigerant amount at shipment lbs. , oz (kg) R410A / [18.3, 293 (8.3)] + [18.3, 293 (8.3)] + [18.3, 293 (8.3)] *1 R410A / [18.3, 293 (8.3)] + [18.3, 293 (8.3)] + [18.3, 293 (8.3)] *1 Refrigerant control Defrost method Electronic expantion valve Outdoor unit cycle def Electronic expantion valve Outdoor unit cycle def 4 Coil face area:(sq. ft.) / Number of rows 37.8 / 2 + 37.8 / 2 + 37.8 / 2 37.8 / 2 + 37.8 / 2 + 37.8 / 2 High pressure switch Yes Yes Overcurrent (CT Method) Yes Yes External finish Polyester powder double coating Polyester powder double coating Height inch (mm) 72-33/64 (1842) 72-33/64 (1842) Product dimension Width Depth Height inch (mm) inch (mm) inch (mm) 144-3/32 (3660) *2 39-3/8 (1000) - 144-3/32 (3660) *2 39-3/8 (1000) - 5 Packing dimension Width inch (mm) - - Depth inch (mm) - - Weight NET lbs(kg) GROSS lbs(kg) [595 (270)] + [595 (270)] + [595 (270)] - [595 (270)] + [595 (270)] + [597 (271)] - Layers limit - - Operation condition (Outdoor) Cool Heat Heat & Cool °F/°C DB °F/°C DB °F/°C WB °F/°C DB °F/°C WB 14 ~ 122 / -10 ~ 50 -13 ~ 75 / -25 ~ 24 -13 ~ 64 / -25 ~ 17.8 14 ~ 75 / -10 ~ 24 - ~ 64 / - ~ 17.8 14 ~ 122 / -10 ~ 50 -13 ~ 75 / -25 ~ 24 -13 ~ 64 / -25 ~ 17.8 6 14 ~ 75 / -10 ~ 24 - ~ 64 / - ~ 17.8 Pipe diameter inch (mm) (Liquid) 5/8 (15.88) (Discharge) 1-1/8 (28.58) (Liquid) 3/4 (19.05) (Discharge) 1-1/8 (28.58) (Suction) 1-1/8 (28.58) (Balance) 1/4 (6.35) (Suction) 1-3/8 (34.92) (Balance) 1/4(6.35) (Over 295 ft. (90m) for ultimate Indoor unit) ((Liquid) 3/4 (19.05) (Discharge) 1-3/8 (34.92) ((Liquid) 7/8 (22.22) (Discharge) 1-3/8 (34.92) Piping Connecting method Pipe length range ft. (m) (Suction) 1-3/8 (34.92)) *3 - - ~ 1640 ( - ~ 500) (Suction) 1-5/8 (41.28)) *3 - ~ 1640 ( - ~ 500) 7 Indoor unit & Outdoor unit height difference (Outdoor unit upper / Outdoor unit lower) ft. (m) 164 / 131 (50 / 40) 164 / 131 (50 / 40) The number of the indoor unit most connection 43 48 Primary accessories - Connection tubing (ID Ø15.88-OD Ø19.05) Color (Munsell code) Ivory (2.6Y7.6/1.1) Ivory (2.6Y7.6/1.1) *1 It's necessary to charge additional refrigerant of 70.5 oz (2.0 kg) per one outdoor unit. *2 Width of product dimention in installation for multiple units is described by using Min unit clearance 60mm. 8 If installation hole pitch is 730mm or using snow-proof ducting, unit clearance should be 180mm. *3 If the longest tubing equivalent length exceeds 295 ft. (90m), increase the sizes of the main tubes by 1 rank for suction tubes, discharge tubes and liquid tubes. With combination model, the specification of each outdoor unit is listed in [ ] , and connected by "+" . 4 - 5 9