Marantz NR1200 Owners Manual - Page 143
ZONE2 Setup
View all Marantz NR1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
Contents Connections Playback Settings Tips Appendix ZONE2 Setup Makes settings for audio playback with ZONE2. 0 Values set for "Volume Limit" and "Pow.On Volume" are displayed according to the setting specified for the volume "Scale". (v p. 116) o Volume Level Set the volume output level. Variable (Default) : 1 - 98 (-79 dB - 18 dB): Volume can be adjusted. Volume is fixed at the desired level. The volume cannot be adjusting using the remote control unit. 0 The dB value is displayed when the "Scale" setting is "-79.5 dB - 18.0 dB". (v p. 116) o Volume Limit Make a setting for maximum volume. 60 (-20 dB) / 70 (-10 dB) / 80 (0 dB) (Default : 70 (-10 dB)) Off: Do not set a maximum volume. 0 This can be set when "Volume Level" is set to "Variable". (v p. 143) 0 The dB value is displayed when the "Scale" setting is "-79.5 dB - 18.0 dB". (v p. 116) o Pow.On Volume Define the volume setting that is active when the power is turned on. Last (Default) : Mute: 1 - 98 (-79 dB - 18 dB): Use the memorized setting from the last session. Always mute when power is turned on. The volume is adjusted to the set level. 0 This can be set when "Volume Level" is set to "Variable". (v p. 143) 0 The dB value is displayed when the "Scale" setting is "-79.5 dB - 18.0 dB". (v p. 116) Front panel Display Rear panel 143 Remote Index