LiftMaster SL3000UL SL3000UL Manual - Page 23

Plug-In Loop Detector Wiring, Outside, Property - manual

Page 23 highlights

P LUG - I N L O O P D E T E C T O R WWAIRRNIINNGG Plug-In Loop Detectors See Accessories CENTER SAFETY EXIT POWER ON DETECT LOOP FAIL FREQUENCY WARNING Not Used SENSITIVITY BOOST ™ W4 GBA MS LINK CENTER SAFETY EXIT The wire MUST be twisted together minimum 6 twists per foot from the end of the loop to the control board. Series Connected Exit Loop Inside Safety Loop Note: Refer to the plug-in loop detector manual for more specific information. SENSOR ALARM ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS 1 3 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT WARNING POWER OVERLOAD MADE IN USA CLOSE STOP OPEN COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CAUTION Outside Safety Loop To AVOID damaging control board, disconnect ALL power to operator before installing plug-in loop detectors. ENGLISH Use a different frequency for every loop detector installed. Plug-In "Safety" Loop Detector - Allows gate to stay open when vehicles are obstructing path. Caution: Suggested for vehicles 14 feet or longer. If the "Inside" and "Outside" safety loops are connected to the same loop detector: ADVERTENCIA • They should be series connected to the detector. • Have the same dimensions. • Have the same number of wire turns. Example of a inside and outside 2 wire turn loop connected in series. (See "Installing Insulated Loop Wire" on next page for more information) ADVERTENCIA Plug-In "Exit" Loop Detector - Allows gate to automatically open for exiting vehicles. PrOopuetsritdye Example of a 3 wire turn loop. (See "Installing Insulated Loop Wire" on next page for more information) ADVERTENCIA PropInesritdye PRECAUCIÓN Contact your local dealer for information about plug-in loop detectors. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

21
PLUG-IN LOOP DETECTOR WIRING
CENTER
SAFETY
EXIT
CENTER
SAFETY
EXIT
FIRE
DEPT.
1
3
STRIKE
OPEN
RADIO
RECEIVER
TIMER
SYSTEM ON
EXIT
LOOP
ALARM
SENSOR
REVERSE
SENSOR
OPEN
STOP
CLOSE
SAFETY
LOOP
CENTER
LOOP
GATE
LOCKED
60
POWER
OVERLOAD
OFF
W4
OPEN LEFT
DC-BACKUP
ALARM
SENSOR
OPEN RIGHT
3
SENSORS
RESET
MOTOR
1
3
1
3
COMMAND
PROCESSED
ON
G
B
MS LINK
A
MADE IN USA
DETECT
BOOST
LOOP FAIL
POWER ON
FREQUENCY
SENSITIVITY
Outside
Property
Inside
Property
Not Used
Plug-In Loop Detectors
See Accessories
Contact your local dealer for information
about plug-in loop detectors.
The wire MUST be
twisted together
minimum 6 twists
per foot
from the
end of the loop to
the control board.
NOTE:
Refer to the plug-in loop detector
manual for more specific information.
Plug-In “Safety” Loop Detector -
Allows gate to
stay open when vehicles are obstructing path.
Caution: Suggested for vehicles 14 feet or longer.
If the “
Inside
” and “
Outside
” safety loops are
connected to the same loop detector:
• They should be series connected to the detector.
• Have the same dimensions.
• Have the same number of wire turns.
Example of a inside and outside 2 wire turn loop
connected in series. (See “Installing Insulated Loop
Wire” on next page for more information)
Plug-In “Exit” Loop Detector -
Allows gate to
automatically open for exiting vehicles.
Example of a 3 wire turn loop. (See “Installing
Insulated Loop Wire” on next page for more
information)
To AVOID damaging control board, disconnect ALL power to
operator before installing plug-in loop detectors.
Use a different frequency for every loop detector installed.
Inside
Safety Loop
Series Connected
Outside
Safety Loop
Exit Loop
CAUTION