f a c tor y in s ta l l e d d c 2 0 0 0 ™ c onne c tion DC 2 0 0 0 ™ S t a r t u p Plug in the 12 pin plug into the DC2000™ control unit. Make sure the "System ON" and "Charge OK" LEDs are lit. If the "Battery Low" led comes on, the battery needs to charge before it can be used. CLASS I, II, III, IV Make sure "Gate Direction" setting on DC2000™ is set the same as the OmniControl™ board setting. See Adjustments. Adjust "Reverse Sensor" setting. See Adjustment Reversing Sensor(s). Socket Reset button and interlock wires, Do Not Remove. 120Vac Power Failure Manual Mode Push and Hold to operate gate. Auto Mode Gate automatically opens. 120Vac Power On, OmniControl™ Board Malfunction Turn the 120Vac power off then push and Hold to operate gate. Turn the 120Vac power off then gate opens automatically. Note: All devices wired to the DC2000™ MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControl™ board and surge suppressor. Typical Auto Mode Example: If the DC2000 is "automatically opening" the gate due to a power failure (auto mode), any manual command such as "One-Button", "Three Push Button", "Key Switch", "Photoelectric Sensor" or "Edge Sensor" will cancel the automatic mode of the DC2000™. After such cancellation, the DC2000™ will continue to operate in "manual mode" until 120Vac power is restored. DC 2 0 0 0 ™ 1 2 V d c R a d i o R e c e i v e r ( N o t P r o v i d e d ) The DC2000™ needs a separate 12Vdc radio receiver to give remote commands to the operator during a power failure. +12Vdc Jumper P2: to Constant (C) Jumper P3: to 12 Volt 1 2 3 315 MHz 12 VDC 4 See Accessories 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

19
FACTORY INSTALLED DC2000™ CONNECTION
DC2000™ Startup
Plug in the 12 pin plug into the DC2000™ control unit. Make sure
the “
System ON
” and “
Charge OK
” LEDs are lit. If the “
Battery
Low
” led comes on, the battery needs to charge before it can be
used.
Make sure “
Gate Direction
” setting on DC2000™ is set the same
as the OmniControl™ board setting. See Adjustments.
Adjust
“Reverse Sensor”
setting. See Adjustment
Reversing Sensor(s).
CLASS I, II, III, IV
Socket
Reset button and interlock wires, Do Not Remove.
Push and
Hold
to operate gate.
Turn the 120Vac power off then push and
Hold
to operate gate.
120Vac Power Failure
120Vac Power On, OmniControl™ Board Malfunction
Auto Mode
Manual Mode
NOTE:
All devices wired to the DC2000™ MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired
to the OmniControl™ board and surge suppressor.
Typical Auto Mode Example:
If the DC2000 is “automatically opening” the gate due to a power failure (auto mode), any manual
command such as “
One-Button
”, “
Three Push Button
”, “
Key Switch
”, “
Photoelectric Sensor
” or “
Edge Sensor
” will cancel the
automatic mode of the DC2000™. After such cancellation, the DC2000™ will continue to operate in “manual mode” until 120Vac power
is restored.
DC2000™ 12Vdc Radio Receiver (Not Provided)
The DC2000™ needs a separate 12Vdc radio receiver to give remote commands to the operator during a power failure.
315 MHz 12 VDC
1
2
3
4
See Accessories
+12Vdc
Jumper P2:
to Constant (C)
Jumper P3:
to 12 Volt
Turn the 120Vac power off then gate opens automatically.
Gate automatically opens.