LiftMaster SL3000UL SL3000UL Manual

LiftMaster SL3000UL Manual

LiftMaster SL3000UL manual content summary:

  • LiftMaster SL3000UL | SL3000UL Manual - Page 1
    OWNER'S MANUAL SL3000UL™ VEHICULAR SLIDE GATE OPERATOR THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES. INTENDED FOR PROFESSIONAL INSTALLATION ONLY. UL325 UL991 compliant compliant
  • LiftMaster SL3000UL | SL3000UL Manual - Page 2
  • LiftMaster SL3000UL | SL3000UL Manual - Page 3
    ÓN Operation Built-In Reset Switch 32 Audio Alarm 32 EMERGENCY MANUAL RELEASE 33 Accessories 34 SPPRAECNAUICSIÓNH SPANISH SPANISH wiring diagrams 35-42 troubleshooting 43-44 repair parts Repair Part Illustrations 45 How to Order Repair Parts 46 Part Names and Numbers 46 installation
  • LiftMaster SL3000UL | SL3000UL Manual - Page 4
    Specifications and Warnings SL 3 0 0 0 UL ™ M o d e l s O V E R V I E W Front View Heater Single Motor Models Back View Cover SL3000UL™ (Single Motor) 1/2 HP Motor, 120Vac, 4 Amp. Maximum Gate Length - 37 ft. Maximum Gate Weight - 1000 lbs. Maximum Pull - 105 lbs. SL3000ULDC™ (Single Motor) 1/2
  • LiftMaster SL3000UL | SL3000UL Manual - Page 5
    service the general public. Class IV - Restricted access vehicular gate operator A vehicular gate operator classes. Gate Operator Entrapment Protection UL325 Slide Gate Operator Installation Classification open and close directions of gate travel. For Example: For a gate system that is installed
  • LiftMaster SL3000UL | SL3000UL Manual - Page 6
    • Vertical Posts • Photoelectric Sensors • Instructional and Precautionary Signage 4. Install the gate operator only when: a. T he operator is appropriate for the construction and the usage class of the gate. b. A ll openings of a horizontal slide gate are guarded or screened from the
  • LiftMaster SL3000UL | SL3000UL Manual - Page 7
    and for barbed wire shall not be less than 6 feet (1.83 m) above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.7 Protrusions shall not
  • LiftMaster SL3000UL | SL3000UL Manual - Page 8
    in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. WARNING CAUTION Property owners MUST never mount any gate operating device near the gate's path! ENGLISH Property owners MUST never allow
  • LiftMaster SL3000UL | SL3000UL Manual - Page 9
    SDEanCIngysPiecAdlreReDLSoaEoVfepICtnyEsAiRdeUTProCEpeINrÓtyCNIA 7 Gate Rail Stops For safety reasons, physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator. This will assure that the gate does not derail while opening or closing fully
  • LiftMaster SL3000UL | SL3000UL Manual - Page 10
    vehicles 14 feet or longer. See Loop Detector Wiring. PRECAUCIÓN Gate Rail Stops For safety reasons, physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator. This will assure that the gate does not derail while opening or closing fully. SPANISH 8
  • LiftMaster SL3000UL | SL3000UL Manual - Page 11
    Installation I N S T A LL A T I O N S E T U P s Front or Rear Position with Single Operator UL approved catch roller with safety cover. Front Position 2 inch wire grid safety screen 48 inches high. Low Voltage UL approved conduit High Voltage UL approved conduit Maximum gate length 37 ft.
  • LiftMaster SL3000UL | SL3000UL Manual - Page 12
    stop at least five inches from an obstructing wall. 5" End View of Gate and Wall Note: For safety reasons, physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator. This will assure that the gate does not derail while opening or closing fully. 10
  • LiftMaster SL3000UL | SL3000UL Manual - Page 13
    operator 8.25" Conduit area without battery back-up. 13" 4 Concrete Anchors 1/2" x 3 1/2" High voltage conduit. Above Ground 6" Low voltage conduit. Suggested installation can be U-bolted to mounting plate and cemented in ground. Power and control wiring should be run in separate conduits. 11
  • LiftMaster SL3000UL | SL3000UL Manual - Page 14
    with gate in open position. Rear Operator Position WARNING Cut the chain slot 17 1/2" high on cover. CAUTION ENGLISH Low idler pulley position. ADVERTENCIA c h ain d i s tan c e an d h ei g h t on g ate CORRECT INSTALLATION INCORRECT INSTALLATION 2 inch ADVERTENCIA wire grid safety
  • LiftMaster SL3000UL | SL3000UL Manual - Page 15
    11 9 STRIKE OPEN RADIO RECEIVER GATE LOCKED 14 SAFETY LOOP 12 CENTER LOOP 10 RESET MOTOR CLOSE STOP OPEN 4 POWER OVERLOAD 5 MADE IN USA 6 UL Alarm Connection Safety Sensors Connection CENTER SAFETY EXIT Omni Option Board Connection 1 1HP Connection - Factory installed SL3000UL1HP™ Models
  • LiftMaster SL3000UL | SL3000UL Manual - Page 16
    ENSURE proper operation of external devices: • ENSURE bare wires make good contact inside removable terminal connections. • DO NOT let wire insulation interfere with connection. Remote NOT Included 315 MHz Factory Installed Radio Receiver Card Reader Separate power for card reader. Push Button Dry
  • LiftMaster SL3000UL | SL3000UL Manual - Page 17
    . WARNor IdaNmaGge to operator. WWAARRNNIINNGG All power wiring should be on a dedicated circuit and well protected. NOTE: Calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability of wire installation. 120Vac Power Wire 1/2 HP and Dual Motor 1 HP 16 Gauge
  • LiftMaster SL3000UL | SL3000UL Manual - Page 18
    each operator. WARNING Input power 120Vac, 60 Hz. Earth Ground Rod Highly Recommended! See previous page. 120Vac Power Wire 1/2 HP and Dual Motor 1 white and ground wire from the heater to the 120Vac power supply as shown. When the heater switch is left in the "ON" position, the heater will turn on
  • LiftMaster SL3000UL | SL3000UL Manual - Page 19
    SENSOR ALARM Shield wire MUST be grounded to master operator Only. W4 G B A MS LINK CENTER SAFETY EXIT CLOSE STOP OPEN ALARM SENSOR COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR ® OmniControl Surge SuppressorPatenPt
  • LiftMaster SL3000UL | SL3000UL Manual - Page 20
    W4 G B A MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA CENTER
  • LiftMaster SL3000UL | SL3000UL Manual - Page 21
    "Reverse Sensor" setting. See Adjustment Reversing Sensor(s). Socket Reset button and interlock wires, Do Not Remove. 120Vac Power Failure Manual Mode Push and Hold to operate gate. Auto Mode Gate automatically opens. 120Vac Power On, OmniControl™ Board Malfunction Turn the 120Vac power
  • LiftMaster SL3000UL | SL3000UL Manual - Page 22
    wires, Do Not Remove. Push and HOLD button to Open. Push button again and HOLD to Close. 1234567 Manual Key Switch See Accessories Turn and HOLD key to Open. Turn key again and HOLD to Close. Manual 3-Button N.O. 3 N.O. 2 N.O. 1 Com 4 Com 4 Com 4 Push and HOLD a button to operate. DC
  • LiftMaster SL3000UL | SL3000UL Manual - Page 23
    MADE IN USA CLOSE STOP OPEN COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CAUTION Outside Safety Loop To AVOID damaging control board, disconnect ALL power to operator before installing plug-in loop detectors. ENGLISH
  • LiftMaster SL3000UL | SL3000UL Manual - Page 24
    should be series connected to the detector • Have the same dimensions. • Have the same number of wire turns (See table below). 120Vac "Exit" Loop Detector - Allows gate to automatically open for 5 exiting vehicles. 6 Exit Loop Installing Insulated Loop Wire Number of Wire Turns Needed for
  • LiftMaster SL3000UL | SL3000UL Manual - Page 25
    signal the gate operator to stop and reverse. Property WARNING owners are obligated to test edges monthly. See Accessories. Parallel Connection Gate in Open Position CAUTION ENGLISH Open Sensor on Wall ADVERTENCIA Open Sensor on Wall Open Sensor on Gate ADVERTENCIA Gate in Open Position
  • LiftMaster SL3000UL | SL3000UL Manual - Page 26
    W4 GBA MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA SENSOR
  • LiftMaster SL3000UL | SL3000UL Manual - Page 27
    W4 wire ONLY when installing a 3 button station, stop button, or QCC. CENTER SAFETY EXIT SENSOR ALARM W4 G B A MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED
  • LiftMaster SL3000UL | SL3000UL Manual - Page 28
    B A MS LINK ALARM SENSOR DC-BACKUP RADIO SYSTEM ON SENSORS REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER ADVERTENCIA OVERLOAD MADE IN
  • LiftMaster SL3000UL | SL3000UL Manual - Page 29
    use of CONSTANT OPERATION on residential operators is PROHIBITED. remote control transmission. PAWRDEAVCREANRUITNCEIGNÓCNIA With the jumper in (C) constant position, the contacts will stay closed as long as the remote control continues transmitting. Push and HOLD remote button to open or close gate
  • LiftMaster SL3000UL | SL3000UL Manual - Page 30
    Learn Button Programming Radio Receiver: 1. Press and release the "Learn " button on the receiver. The learn indicator light will glow steadily for 30 seconds. 2. Within 30 seconds, press and hold the button on the hand-held remote. The operator will now operate when the push button on the remote
  • LiftMaster SL3000UL | SL3000UL Manual - Page 31
    Operators need to be connected by M/S LINK. See M/S Link. ALARM SENSOR ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR
  • LiftMaster SL3000UL | SL3000UL Manual - Page 32
    RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA CENTER SAFETY EXIT DC 2 0 0 0 ™ R e v e r s e S e n s o r The DC2000™ has a separate reverse sensor that will need to be adjusted. The 120Vac CLASS I, II, III, IV operator power
  • LiftMaster SL3000UL | SL3000UL Manual - Page 33
    the gate operator properly WARNSIaNvGe These Instructions. can increase the risk of injury or death. Chamberlain Elite professional. 10. MAINTENANCE: 1. Disconnect power before servicing. CAUTION 2. The gate area should be kept clean to insure proper operation. 3. Check for belt tightness
  • LiftMaster SL3000UL | SL3000UL Manual - Page 34
    . If the audio alarm goes off, always check the gate area for: • Obstructions in the gate path. • Damage to the gate and/or gate operator. Pressing the reset switch will stop a moving gate during a normal open/close cycle, like a stop button. The operator does NOT need to be reset after doing this
  • LiftMaster SL3000UL | SL3000UL Manual - Page 35
    . Manu. 2 Rm NOTE: Use the dedicated breaker switch to disconnect power to the operator. T u r n t h e p o w e r O FF ! Push the crank tool in hole. Safety releases will separate. Turn the crank to open the gate. Remove crank tool. Note: You may use a cordless power drill (6"/sec) for quicker
  • LiftMaster SL3000UL | SL3000UL Manual - Page 36
    inch V-Groove Power Wheels Series 6 inch Remote Controls Relay Adapter Module Part # Q400MAU Quick Close Circuit (QCC) Part # OQCCOMNI For more information about accessories: www.chamberlain.com 3-Button Control Station Part # 02-103 Omni Option Board Part # OOMNIEXB UL Approved Round Sensing
  • LiftMaster SL3000UL | SL3000UL Manual - Page 37
    RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA Left relay adapter module (Optional) UL alarm NOTE: Limit Limit Box switch wiring assy differs when DC2000™ is used. Right Factory Heater NOTE: Wires into main power and draws
  • LiftMaster SL3000UL | SL3000UL Manual - Page 38
    Input Power 120Vac Strike Open Exit Loop Radio Receiver - Radio Receiver Fire Dept Key Switch Radio Receiver + Omni Option Board Limit Switch Red N.O. Motor White Normally Closed (No Wire) Motor Black Limit Switch Brown Com Motor Red Purple Com Blue N.O. Limit Switch Yellow Com Limit Switch Orange
  • LiftMaster SL3000UL | SL3000UL Manual - Page 39
    RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA Left relay adapter module (Optional) UL alarm NOTE: Limit Limit Box switch wiring assy differs when DC2000™ is used. Right Factory Heater NOTE: Wires into main power and draws
  • LiftMaster SL3000UL | SL3000UL Manual - Page 40
    Input Power 120Vac Strike Open Exit Loop Radio Receiver - Radio Receiver Fire Dept Key Switch Radio Receiver + Omni Option Board Limit Switch Red N.O. Motor White Normally Closed (No Wire) Motor Black Limit Switch Brown Com Motor Red Purple Com Blue N.O. Limit Switch Yellow Com Limit Switch Orange
  • LiftMaster SL3000UL | SL3000UL Manual - Page 41
    FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA Left Motor Relay Adapter Module (Optional) UL Alarm Limit Box Assy Right Factory Heater Note: Wires into main power and draws 3 amps. to J10
  • LiftMaster SL3000UL | SL3000UL Manual - Page 42
    Out Out Out - Out Out 0V 120Vac 0V - 120Vac 0V 2 Motors Input OmniControl™ Surge Suppressor G M/S Link (G) B M/S Link (B) A M/S Link (A) Fire Dept. Key Switch (7) Fire Dept. Key Switch (8) Strike Open Push Button (9) Strike Open Push Button (10) Radio Receiver - (11) Radio Receiver (12) Radio
  • LiftMaster SL3000UL | SL3000UL Manual - Page 43
    1234567 J5 DC-BACKUP 2 3 SENSOR ALARM SYSTEM ON SENSORS 1 3 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE
  • LiftMaster SL3000UL | SL3000UL Manual - Page 44
    to it alone. Normal operation will be controlled by separate devices wired to the OmniControl™ board and surge suppressor. Radio Receiver 315 MHz 12Vdc to J6 Pin 3,4 OmniControl™ Board (Sensor) 1 2 3 4 5 6 7 J20 1 Open N.O. 2 Close N.O. 3 Stop N.O. Manual Three Button Dry Contact 6 + 12Vdc
  • LiftMaster SL3000UL | SL3000UL Manual - Page 45
    Troubleshooting The Gate Will Not Operate with Remote: OFF OPEN LEFT ON OPEN RIGHT STRIKE RADIO OPEN RECEIVER GATE LOCKED The radio receiver LED on the CENTER LOOP control board remains "ON" when using the remote control. 1. Probable Cause: Stuck remote control button. Solution: Unstick
  • LiftMaster SL3000UL | SL3000UL Manual - Page 46
    more and try again. 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. Check inputs for command. 1. Any re-new command will resume
  • LiftMaster SL3000UL | SL3000UL Manual - Page 47
    Repair Parts repair part i l l u s tration s SL DM SL *Q029 Q033 Q254 ODC2000SL Q024 DM / 1 HP 312HM Q030 K75-50893 Q039 Q237 Q020 Q025 Q021 Q027 *Q018 Q016 Q014 Q015 *Q013 Master Link Chain G6518SL OFF ON OFF ON Q028
  • LiftMaster SL3000UL | SL3000UL Manual - Page 48
    to: THE CHAMBERLAIN GROUP, INC. Technical Support Group 6020 S. Country Club Road Tucson, Arizona 85706 repair part names and numbers Crank Housing Kit - K75-50932 - Manual Crank not Included Power Back-Up Unit - ODC2000SL - Drive Belt DC SL - Drive Belt DC SL (DM) - Back-Up Motor DC 12V - Chassis
  • LiftMaster SL3000UL | SL3000UL Manual - Page 49
    all wire connections are securely fastened. 13. Review typical maintenance on operator. 14. Schedule periodic maintenance on operator by qualified service technician. 15. Inquire about Manufacturers "operator warranty". (Warranty card included with operator.) 16. Inquire about separate "installation
  • LiftMaster SL3000UL | SL3000UL Manual - Page 50
    [and that the SL3000UL™ is free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase]. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and
  • LiftMaster SL3000UL | SL3000UL Manual - Page 51
  • LiftMaster SL3000UL | SL3000UL Manual - Page 52
    SL3000UL™ 01-50388G UL325 UL991 compliant compliant 845 Larch Avenue Elmhurst, Illinois 60126-1196 © 2009, The Chamberlain Group, Inc. - All Rights Reserved
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

O W N E R ’ S
M A N U A L
SL3000UL™
VEHICULAR SLIDE GATE OPERATOR
THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY
AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
UL325
compliant
UL991
compliant
INTENDED FOR PROFESSIONAL INSTALLATION ONLY.