Entry Codes When adding entry codes, note the following: Each assigned Entry Code must be entered with the set amount of allowable digits (3-9). For example, if you assign "4578" as a resident's Entry Code, but the system is set for 5 digits, the visitor will have to enter "04578" to enter the building. Add a Basic Entry Code: 50 Add an Entry Code ONLY. For adding or editing full function Entry Codes (i.e., codes with additional options such as use schedules, door assignments, etc.). 1 Press Then 2 Enter Entry Code (3-9 digits). Then (#) Note: Factory Setting for Entry Code Length is 4 digits See "Entry Code Length" above. Entry Codes / Access Cards Entry Codes / Access Cards Example: 1 2 Adds Entry Code "5400". Note: A basic Entry Code will be active with the current date, time and never deactivates, unlock all controlled doors, with no time constraint (i.e., can be used 24 hours a day, 7 days a week). * If you make an error during an entry, press the asterisk key ( ) to begin again. Access Cards When adding cards, note the following: • If you don't add a facility code or card type, the system will assign the default. The allowable facility code range is 0-255 for 26-bit cards and 0-63 for 30-bit cards. • When entering cards with facility codes: - Enter the facility codes individually when adding cards OR - Enter a default facility code. If you don't, the card will be assigned the default facility code. Add a Basic Card: 80 This programming step allows you to add a card using the card's number. For adding or editing full function cards (i.e., cards with additional options such as use schedules, door assignments, etc.). 1 Press Then 2 Enter Card Number (1-65534). Then (#) 3 Enter Facility Code (0-63 or 0-255, depending on the card type). Then (#) 4 Enter Card Type (26 or 30). Then (#) Required Step Optional Step, Press (#) to Skip. Example: 1 2 3 4 Adds card with number "34432", default Facility Code and 30-bit Card Type. Notes: A basic card will be active with the current system time and never deactivate, unlock all doors connected to the EL25, with no time constraint (i.e., can be used 24 hours a day, 7 days a week). For new records, if you don't add a Facility Code or Card Type, the system will add the defined default values. Page 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Page 20
Entry Codes
Access Cards
1
Press
2
Enter Entry Code (3-9 digits). Then (
#
)
Factory Setting for Entry Code Length is 4 digits
See
“Entry Code Length”
above.
Add an Entry Code
ONLY
. For adding or editing full function Entry Codes (i.e., codes with additional options
such as use schedules, door assignments, etc.).
Note:
A basic Entry Code will be active with the current date, time and never deactivates, unlock all controlled
doors, with no time constraint (i.e., can be used 24 hours a day, 7 days a week).
Example:
Each assigned Entry Code must be entered with the set amount of allowable digits (3-9)
. For example, if
you assign “4578” as a resident's Entry Code, but the system is set for 5 digits, the visitor will have to enter
“04578” to enter the building.
When adding entry codes, note the following:
Adds Entry Code “5400”.
Then
Entry Codes / Access Cards
Entry Codes / Access Cards
50
Add a Basic Entry Code:
2
1
Note:
1
Press
2
Enter Card Number (1-65534). Then (
#
)
3
Enter Facility Code (0-63 or 0-255, depending on the card type). Then (
#
)
4
Enter Card Type (26 or 30). Then (
#
)
This programming step allows you to add a card using the card's number. For adding or editing full function
cards (i.e., cards with additional options such as use schedules, door assignments, etc.).
Notes:
A basic card will be active with the current system time and never deactivate, unlock all doors connected
to the EL25, with no time constraint (i.e., can be used 24 hours a day, 7 days a week).
For new records, if you don't add a Facility Code or Card Type, the system will add the defined default values.
Example:
If you don't add a facility code or card type, the system will assign the default. The allowable facility code
range is 0-255 for 26-bit cards and 0-63 for 30-bit cards.
When entering cards with facility codes:
When adding cards, note the following:
Adds card with number “34432”, default Facility Code and 30-bit Card Type.
Then
Enter the facility codes individually when adding cards
OR
Enter a default facility code. If you don't, the card will be assigned the default facility code.
3
4
Add a Basic Card:
80
1
2
Required Step
Optional Step,
Press (
#
) to Skip.
If you make an error during an entry, press the asterisk key (
*