HP StorageWorks 7110 HP StorageWorks Virtual Array 7000 Family User and Servic - Page 97

Hot Swappable FRUs, Table 22

Page 97 highlights

Hot Swappable FRUs A field replaceable unit (FRU) is "hot swappable" if it can be removed and replaced while the array is powered on, without disrupting I/O activity. A FRU is not hot swappable if all applications and file systems must be terminated, or a host shutdown must be performed, before it can be replaced. Table 22 shows hot swappable FRUs for the controller enclosure and the disk enclosure. Table 22 Hot Swappable FRUs Enclosures FRU Hot Swappable Controller & Disk Disk Drive Yes Controller & Disk Power Module Yes Controller Single Controller No Controller Dual Controller Yes* Controller (VA 7100 Only) GBIC Yes* Controller & Disk Disk Controller & Disk Fiber Optic Cables Yes* LCC Yes Midplane Assembly No *Only if the OS supports controller failover. Servicing & Upgrading Servicing & Upgrading 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

Servicing & Upgrading
97
Servicing & Upgrading
Hot Swappable FRUs
A field replaceable unit (FRU) is “hot swappable” if it can be removed and
replaced while the array is powered on, without disrupting I/O activity. A FRU
is
not
hot swappable if all applications and file systems must be terminated, or
a host shutdown must be performed, before it can be replaced.
Table 22
shows
hot swappable FRUs for the controller enclosure and the disk enclosure.
Table 22
Hot Swappable FRUs
*Only if the OS supports controller failover.
Enclosures
FRU
Hot
Swappable
Controller & Disk
Disk Drive
Yes
Controller & Disk
Power Module
Yes
Controller
Single Controller
No
Controller
Dual Controller
Yes*
Controller (VA 7100 Only)
GBIC
Yes*
Controller & Disk
Fiber Optic Cables
Yes*
Disk
LCC
Yes
Controller & Disk
Midplane Assembly
No