HP PageWide Pro 750 Air Flow Repair Kit Install Guide - Page 8

Remove the ACCM.

Page 8 highlights

4.5 4.6 1 2 3 Push up on the guide to release it, and then move it out of the way. REINSTALL TIP: There are some tabs on the sheet-metal side of the guide that install in corresponding holes in the sheet-metal plate. The guide is flat against the sheet metal when it is correctly installed. Disconnect three FFCs (callout 1), push in on the FFC just below the ferrite (callout 2) to release a tab, and then slide the ferrite down and out of the holder (callout 3). 4.7 4.8 3 2 Carefully pry out on the hinge portion of the lower FFC guide to separate it from the ACCM, and then move it out of the way. 4.9 1 Disconnect one connector (callout 1), remove four screws (callout 2) on the sheet-metal plate, and then remove two screws (callout 3) on the ACCM. REINSTALL TIP: Install the four sheet-metal plate screws (callout 2) after installing two screws (callout 3) on the AC control module. Doing so allows the AC module and plate to be repositioned if the four screw holes in the plate are not completely aligned with the corresponding threaded holes in the chassis. 4. 10 Hold the sheet-metal bracket out of the way, and slide the ACCM to the left Remove the ACCM. and away from the printer. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

8
4.7
4.8
4.9
4. 10
Carefully pry out on the hinge portion of the lower FFC guide to separate it
from the ACCM, and then move it out of the way.
Disconnect one connector (callout 1), remove four screws (callout 2) on the
sheet-metal plate, and then remove two screws (callout 3) on the ACCM.
REINSTALL TIP:
Install the four sheet-metal plate screws (callout 2)
after
installing two screws (callout 3)
on the AC control module. Doing so allows the AC module and plate to be
repositioned if the four screw holes in the plate are not completely aligned
with the corresponding threaded holes in the chassis.
Hold the sheet-metal bracket out of the way, and slide the ACCM to the left
and away from the printer.
Remove the ACCM.
4.5
4.6
Push up on the guide to release it, and then move it out of the way.
REINSTALL TIP:
There are some tabs on the sheet-metal side of the guide
that install in corresponding holes in the sheet-metal plate. The guide is
flat against the sheet metal when it is correctly installed.
Disconnect three FFCs (callout 1), push in on the FFC just below the ferrite
(callout 2) to release a tab, and then slide the ferrite down and out of the
holder (callout 3).
1
2
3
1
2
3