HP PageWide Pro 750 Air Flow Repair Kit Install Guide - Page 7

Remove the AC controller module, ACCM PW765/780/785, ACCM PW750/772/777, MFP models, SFP models

Page 7 highlights

4 Remove the AC controller module (ACCM) ((PW765/780/785) Remove the AC controller module (ACCM) ((PW750/772/777) 4.1 3 2 1 Do one of the following: · MFP models: Disconnect two (callout 1/2), and then release the wire harnesses from the guide (callout 3). · SFP models: Disconnect one connector (callout 1), and then release the wire harness from the guide (callout 3). 4.2 2 2 1 4.1 1 2 3 Do one of the following: · MFP models: Disconnect five flat-flexible cables (FFCs) (callout 1) and two connectors (callout 2). · SFP models: Disconnect two connectors (callout 2) and one FFC (callout 3) 4.2 1 Release one tab (callout 1), release three pins (callout 2), and then move the guide out of the way. Loosen two screws (callout 1), and then rotate the guide up and away for the printer to move it out of the way. NOTE: These screws are captive and cannot be removed. 4.3 4.4 1 1 Release one FFC from the guide (callout 1) Remove two screws (callout 1) 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

1
1
7
4.3
4.4
Release one FFC from the guide (callout 1)
Remove two screws (callout 1)
4
Remove the AC controller module
(ACCM) ((PW765/780/785)
Remove the AC controller module
(ACCM) ((PW750/772/777)
1
1
2
2
2
3
4.1
4.2
Release one tab (callout 1), release three pins (callout 2), and then move
the guide out of the way.
Do one of the following:
·
MFP models
: Disconnect two (callout 1/2), and then release the wire
harnesses from the guide (callout 3).
·
SFP models
: Disconnect one connector (callout 1), and then release the
wire harness from the guide (callout 3).
1
1
2
3
4.1
4.2
Loosen two screws (callout 1), and then rotate the guide up and away for
the printer to move it out of the way.
NOTE
: These screws are captive and cannot be removed.
Do one of the following:
·
MFP models
: Disconnect five flat-flexible cables (FFCs) (callout 1) and two
connectors (callout 2).
·
SFP models
: Disconnect two connectors (callout 2) and one FFC (callout 3)