Belkin F5D5131-16 User Guide - Page 12
Troubleshooting - 5 troubleshoot
UPC - 722868510872
View all Belkin F5D5131-16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Troubleshooting Diagnosing Switch Indicators Symptom Power LED does not light after power on. Probable Causes DC power adapter may be defective. Possible Solutions • Check for loose connections. • Check the power outlet by using it for another device. • Replace the DC power adapter. Symptom Port (Link/Act) LED does not light after connection is made. Probable Causes Switch port, network card, or cable may be defective. Possible Solutions • Check that the Switch and attached device are both powered on. • Be sure the network cable is connected to both devices. • Verify that Category 5 or better cable is used for 10/100Mbps connections, and that the length of any cable does not exceed 328 feet (100m). • Check the network card and cable connections for defects. • Replace the defective card or cable if necessary. 12