PRO GRAND RANGES PRO GRAND® RANGES PLANNING INFORMATION ELECTRICAL AND GAS LOCATIONS Typical placement of the electrical and gas supply can be found within the "Cutout and Range Dimensions" located on the product pages. Alternate placement within the supply zone is acceptable. Dual-Fuel ranges may be connected to the power supply with a range supply cord kit (sold separately) or by hard-wiring to the power supply. All-gas ranges may be connected to the power supply with the supplied range cord or by hardwiring. It is the responsibility of the installer to provide the proper wiring components (cord or conduit and wires) and complete the electrical connection as dictated by local codes and ordinances and / or the National Electric Code. The units must be properly grounded. Installation of the range must be planned so that the rough-in of the junction box for the receptacle or conduit connection will allow maximum clearance to the rear of the unit. WARRANTY Limited warranty parts and labor (2 year) See page 310 for additional warranty details. WARNING: All ranges can tip, causing injury. Install anti-tip device packed with range. Thermador Pro Grand® Ranges are CSA approved. ESIGN D CERTIFIED C ER T IF I D E VENTILATION REQUIREMENTS We strongly recommend that a Thermador Professional® Wall or Island Hood or Custom Insert be installed with all Thermador Pro Grand Ranges. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the cooktop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Pro Grand Ranges. For high output gas cooktops (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is recommended. If the cooktop has a grill or griddle, add 150 CFM to the estimated blower capacity. Additional blower capacity may be required for longer duct runs. The following table indicates the ventilation hood options that are recommended for use with Thermador Pro Grand Ranges. Refer to the Ventilation section or www.Thermador.com for a complete selection of Professional ventilation options, blowers, and accessories. WIDTH CONFIGURATION VENTILATION OPTIONS 36" 4 Burners w/Grill or Griddle 6 Burners 36" or 42" Pro Wall Hood 36" Custom Insert with optional blower 42" or 48" Island Hood with optional blower 48" 6 Burners w/Grill or Griddle 48" or 54" Pro Wall Hood 48" Custom Insert with optional blower 54" Island Hood with optional blower 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

PRO GRAND RANGES
23
PRO GRAND
®
RANGES
PLANNING INFORMATION
ELECTRICAL AND GAS LOCATIONS
Typical placement of the electrical and gas supply
can be found within the ”Cutout and Range Dimensions“
located on the product pages. Alternate placement
within the supply zone is acceptable. Dual-Fuel ranges
may be connected to the power supply with a range
supply cord kit (sold separately) or by hard-wiring to the
power supply. All-gas ranges may be connected to the
power supply with the supplied range cord or by hard-
wiring. It is the responsibility of the installer to provide
the proper wiring components (cord or conduit and
wires) and complete the electrical connection as dictated
by local codes and ordinances and / or the National
Electric Code. The units must be properly grounded.
Installation of the range must be planned so that the
rough-in of the junction box for the receptacle or
conduit connection will allow maximum clearance to
the rear of the unit.
WARRANTY
Limited warranty parts and labor (2 year)
See page 310 for additional warranty details.
VENTILATION REQUIREMENTS
We strongly recommend that a Thermador Professional
®
Wall or Island
Hood or Custom Insert be installed with all Thermador Pro Grand Ranges.
Downdraft ventilation should not be used. Do not install a microwave-hood
combination above the cooktop, as these types of units do not provide the
proper ventilation and are not suitable for use with Thermador Pro Grand
Ranges.
For high output gas cooktops (60,000 BTU or greater), the minimum of one
(1) CFM of ventilation per 100 BTU is recommended. If the cooktop has a grill
or griddle, add 150 CFM to the estimated blower capacity. Additional blower
capacity may be required for longer duct runs.
The following table indicates the ventilation hood options that are
recommended for use with Thermador Pro Grand Ranges. Refer to the
Ventilation section or www.Thermador.com for a complete selection of
Professional ventilation options, blowers, and accessories.
WIDTH
CONFIGURATION
VENTILATION OPTIONS
36"
4
Burners w/Grill
or Griddle
6 Burners
36" or 42" Pro Wall Hood
36" Custom Insert with
optional blower
42" or 48" Island Hood with
optional blower
48"
6
Burners w/Grill
or Griddle
48" or 54" Pro Wall Hood
48" Custom Insert with
optional blower
54" Island Hood with optional blower
Thermador Pro Grand
®
Ranges are CSA approved.