Metabo KFM 9-3 RF Operating Instructions - Page 13

Overview, Commissioning

Page 13 highlights

- Use an extraction unit and/or air purifiers - Ensure good ventilation of the workplace and keep clean using a vacuum cleaner Sweeping or blowing stirs up dust - Vacuum or wash the protective clothing Do not blow, beat or brush 4.3 Special safety instructions for mains powered machines: Pull the plug out of the socket before making any adjustments, changing tools, carrying out maintenance or cleaning. Use of a fixed extractor system is recommended. Always install an RCD with a maximum trip current of 30 mA upstream. When the machine is shut down by the RCD, it must be checked and cleaned. See chapter 10. Cleaning. 4.4 Special safety instructions for cordless machines: Remove the battery pack from the machine before making any adjustments, changing tools, maintaining or cleaning. Protect battery packs from water and moisture! Do not expose battery packs to fire! Do not use faulty or deformed battery packs! Do not open battery packs! Do not touch contacts or short-circuit battery packs! A slightly acidic, flammable fluid may leak from defective Li-ion battery packs! If battery fluid leaks out and comes into contact with your skin, rinse immediately with plenty of water. If battery fluid leaks out and comes into contact with your eyes, wash them with clean water and seek medical attention immediately! 5. Overview See page 2. 1 Clamping screws 2 Spindle locking button 3 Additional handle 4 Slide switch 5 Handle 6 Dust filter * 7 Electronic signal indicator * 8 Battery pack release button * 9 Capacity indicator button * 10 Capacity and signal indicator * 11 Battery pack * 12 Graduated collar 13 Adjusting ring 14 Scale 15 Knurled screw * 16 Ripping fence* 17 Support surface ENGLISH en 18 Screw for fixing the ball bearing stationary seal ring 19 Ball bearing stationary seal ring 20 Indexable insert 21 Fastening screw 22 Holder for indexable insert *equipment-specific 6. Commissioning 6.1 For mains powered machines only Before plugging in, check that the rated mains voltage and mains frequency, as stated on the type plate match your power supply. Always install an RCD with a maximum trip current of 30 mA upstream. 6.2 For cordless machines only Dust filter Always fit the dust filter (6) if the surroundings are heavily polluted. The machine heats up faster when the dust filter (6) is fitted. It is protected by the electronics system from overheating (see Section 11.). To fit: See illustration A on page 2. Fit the dust filter (6) as shown. Removal: Holding the dust filter (6) at the edges, raise it slightly and then pull it downwards and remove. Rotating battery pack See illustration B on page 2. The rear section of the machine can be rotated 270° in 3 stages, thus allowing the machine's shape to be adapted to the working conditions. Only operate the machine when it is in an engaged position. Battery pack Charge the battery pack (11) before use. If performance diminishes, recharge the battery pack. The ideal storage temperature is between 10°C and 30°C. Li-Ion battery packs "Li-Power" have a capacity and signal indicator (10): - Press the button (9), the LEDs indicate the charge level. - If one LED is flashing, the battery pack is almost flat and must be recharged. Removing and inserting the battery pack Removal: Press the battery pack release (8) button and pull the battery pack (11) downwards. Inserting: Slide in the battery pack (11) until it engages. 6.3 Install parallel guide/ripping fence See illustration on page 2. 1. Place the parallel guide/ripping fence (16) as shown. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

ENGLISH
en
13
-
Use an extraction unit and/or air purifiers
-
Ensure good ventilation of the workplace and
keep clean using a vacuum cleaner Sweeping or
blowing stirs up dust
-
Vacuum or wash the protective clothing Do not
blow, beat or brush
4.3
Special safety instructions for mains
powered machines:
Pull the plug out of the socket before making any
adjustments, changing tools, carrying out
maintenance or cleaning.
Use of a fixed extractor system is recommended.
Always install an RCD with a maximum trip current
of 30 mA upstream. When the machine is shut down
by the RCD, it must be checked and cleaned. See
chapter 10. Cleaning.
4.4
Special safety instructions for cordless
machines:
Remove the battery pack from the machine before
making any adjustments, changing tools,
maintaining or cleaning.
Protect battery packs from water and
moisture!
Do not expose battery packs to fire!
Do not use faulty or deformed battery packs!
Do not open battery packs!
Do not touch contacts or short-circuit battery packs!
A slightly acidic, flammable fluid may leak
from defective Li-ion battery packs!
If battery fluid leaks out and comes into
contact with your skin, rinse immediately
with plenty of water. If battery fluid leaks out
and comes into contact with your eyes, wash them
with clean water and seek medical attention
immediately!
See page 2.
1
Clamping screws
2
Spindle locking button
3
Additional handle
4
Slide switch
5
Handle
6
Dust filter *
7
Electronic signal indicator *
8
Battery pack release button *
9
Capacity indicator button *
10
Capacity and signal indicator *
11
Battery pack *
12
Graduated collar
13
Adjusting ring
14
Scale
15
Knurled screw *
16
Ripping fence*
17
Support surface
18
Screw for fixing the ball bearing stationary seal
ring
19
Ball bearing stationary seal ring
20
Indexable insert
21
Fastening screw
22
Holder for indexable insert
*equipment-specific
6.1
For mains powered machines only
Before plugging in, check that the rated mains
voltage and mains frequency, as stated on the
type plate match your power supply.
Always install an RCD with a maximum trip
current of 30 mA upstream.
6.2
For cordless machines only
Dust filter
Always fit the dust filter (6) if the surroundings
are heavily polluted.
The machine heats up faster when the dust
filter (6) is fitted. It is protected by the
electronics system from overheating (see Section
11.).
To fit:
See illustration A on page 2.
Fit the dust filter (6) as shown.
Removal:
Holding the dust filter (6) at the edges,
raise it slightly and then pull it downwards and
remove.
Rotating battery pack
See illustration B on page 2.
The rear section of the machine can be rotated 270°
in 3 stages, thus allowing the machine's shape to be
adapted to the working conditions. Only operate the
machine when it is in an engaged position.
Battery pack
Charge the battery pack (11) before use.
If performance diminishes, recharge the battery
pack.
The ideal storage temperature is between 10°C and
30°C.
Li-Ion battery packs "Li-Power" have a capacity and
signal indicator (10):
-
Press the button (9), the LEDs indicate the charge
level.
-
If one LED is flashing, the battery pack is almost
flat and must be recharged.
Removing and inserting the battery pack
Removal:
Press the battery pack release (8) button
and pull the battery pack (11) downwards
.
Inserting:
Slide in the battery pack (11) until it
engages.
6.3
Install parallel guide/ripping fence
See illustration on page 2.
1.
Place the parallel guide/ripping fence (16) as
shown.
5.
Overview
6.