INTRODUCTION SPECIFICATIONS This model is intended for use in vehicular swing gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight/Length 90 Degree Travel Time* Maximum Travel Range* Maximum Daily Cycle Rate Maximum Duty Cycle Operating Temperature Expansion Board Inherent Entrapment Protection (Type A) External Entrapment Protection (Type B1 and/or Type B2) Class I & II 120 Vac, .5 Amps (6.5 Amps including Accessory Outlets) 12 Vdc Battery Run / Battery Backup 12 Vdc, 500mA max. for ON + SW (switched) 12 Vdc at 30 watts max. 400 lbs. (181.4 kg)/16 ft. (4.9 m) 600 lbs. (272.2 kg)/12 ft. (3.7 m) 700 lbs. (317.5 kg)/10 ft. (3 m) 800 lbs. (362.9 kg)/8 ft. (2.4 m) 1000 lbs. (543.5 kg)/6 ft. (1.8 m) < 17 seconds 115 degrees 250 cycles/day Continuous Without Heater: -20°C to 60°C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 140°F) Optional Dual - RPM and Current Sense 3 inputs on main board - 3 photoelectric sensors and up to 2 edge sensors *Travel time and range are affected by A and B mounting dimensions 27.66" 18.77" 14.8" 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

6
SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
INTRODUCTION
27.66"
18.77"
14.8"
Usage Classification
Class I & II
Main AC Supply
120 Vac, .5 Amps (6.5 Amps including Accessory Outlets)
System Operating Voltage
12 Vdc Battery Run / Battery Backup
Accessory Power
12 Vdc, 500mA max. for ON + SW (switched)
Solar Power Max
12 Vdc at 30 watts max.
Maximum Gate Weight/Length
400 lbs. (181.4 kg)/16 ft. (4.9 m)
600 lbs. (272.2 kg)/12 ft. (3.7 m)
700 lbs. (317.5 kg)/10 ft. (3 m)
800 lbs. (362.9 kg)/8 ft. (2.4 m)
1000 lbs. (543.5 kg)/6 ft. (1.8 m)
90 Degree Travel Time*
< 17 seconds
Maximum Travel Range*
115 degrees
Maximum Daily Cycle Rate
250 cycles/day
Maximum Duty Cycle
Continuous
Operating Temperature
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Expansion Board
Optional
Inherent Entrapment Protection (Type A)
Dual - RPM and Current Sense
External Entrapment Protection (Type B1 and/or Type B2)
3 inputs on main board - 3 photoelectric sensors and up to 2 edge sensors